• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Recent Advances in Bubble-Assisted Liquid Hole Multipliers in Liquid Xenon (1708.06645)

    E. Erdal, L. Arazi, A. Tesi, A. Roy, S. Shchemelinin, D. Vartsky, A. Breskin
    Nov. 3, 2018 physics.ins-det
    We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced ionization electrons and primary scintillation photons in the noble liquid. Four types of LHM electrodes were investigated: a THGEM, standard double-conical GEM, 50 $\mu$m-thick single-conical GEM (SC-GEM) and 125 $\mu$m-thick SC-GEM - all coated with CsI photocathodes. The 125 $\mu$m-thick SC-GEM provided the highest electroluminescence (EL) yields, up to ~400 photons per electron over 4$\pi$ with an RMS pulse-height resolution reaching 5.5% for events comprising ~7000 primary electrons. Applying a high transfer field across the bubble, the EL yield was further increased by a factor of ~5. The feasibility of a vertical-mode LHM, with the bubble confined between two vertical electrodes, and the operation of a two-stage LHM configuration were demonstrated for the first time. We combine electrostatic simulations with observed signals to draw conclusions regarding the location of the liquid-gas interface and suggest an explanation for the observed differences in EL yield between the investigated electrodes.
  • The Next White (NEW) detector (1804.02409)

    F. Monrabal, J.J. Gómez-Cadenas, J.F. Toledo, V. Álvarez, J.M. Benlloch-Rodríguez, S. Cárcel, J.V. Carrión, R. Esteve, R. Felkai, V. Herrero, A. Laing, A. Martínez, M. Musti, M. Querol, J. Rodríguez, A. Simón, C. Sofka, J. Torrent, R. Webb, J.T. White, C. Adams, L. Arazi, C.D.R. Azevedo, K. Bailey, F. Ballester, F.I.G.M. Borges, A. Botas, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, S. Johnston, B.J.P. Jones, L. Labarga, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, G. Martínez-Lema, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Munoz Vidal, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, J. Renner, J. Repond, S. Riordan, C. Romo, L. Ripoll, L. Rogers, F.P. Santos, J.M.F. dos Santos, M. Sorel, T. Stiegler, J.F.C.A. Veloso, N. Yahlali
    April 6, 2018 physics.ins-det
    Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for $\beta\beta 0\nu$ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures.
  • Electron drift properties in high pressure gaseous xenon (1804.01680)

    NEXT Collaboration: A. Simón, R. Felkai, G. Martínez-Lema, F. Monrabal, D. González-Díaz, M. Sorel, J.A. Hernando Morata, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R. Azevedo, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, L.M.P. Fernandes, P. Ferrario, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, V. Herrero, S. Johnston, B.J.P. Jones, M.Kekic, L. Labarga, A. Laing, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, B. Palmeiro, A. Para, J. Pérez, M. Querol, J. Renner, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, J.M.F. dos Santos, C. Sofka, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    April 5, 2018 hep-ex, nucl-ex, physics.ins-det
    Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent amplification, a 1:2 scale model of the future NEXT-100 detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December 2016. The drift parameters have been measured using $^{83m}$Kr for a range of reduced drift fields at two different pressure regimes, namely 7.2 bar and 9.1 bar. The results have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal diffusion and transverse diffusion.
  • Calibration of the NEXT-White detector using $^{83m}\mathrm{Kr}$ decays (1804.01780)

    NEXT Collaboration: G. Martínez-Lema, J.A. Hernando Morata, B. Palmeiro, A. Botas, P. Ferrario, F. Monrabal, A. Laing, J. Renner, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R. Azevedo, K. Bailey, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, V. Herrero, S. Johnston, B.J.P. Jones, M.Kekic, L. Labarga, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A.D. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, P. Novella, D.R. Nygren, A. Para, J. Pérez, M. Querol, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, J.M.F. dos Santos, A. Simón, C. Sofka, M. Sorel, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlalib
    April 5, 2018 hep-ex, physics.ins-det
    The NEXT-White (NEW) detector is currently the largest radio-pure high pressure gas xenon time projection chamber with electroluminescent readout in the world. NEXT-White has been operating at Laboratorio Subterr\'aneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed with $^{83m}\mathrm{Kr}$ decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event position which is mainly caused by variations in solid angle coverage. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.55 $\pm$ 0.01) % FWHM in the full chamber and (3.88 $\pm$ 0.04) % FWHM in a restricted fiducial volume. Using naive 1/$\sqrt{E}$ scaling, these values translate into FWHM resolutions of (0.592 $\pm$ 0.001) % FWHM and (0.504 $\pm$ 0.005) % at the $Q_{\beta\beta}$ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.
  • Measurement of radon-induced backgrounds in the NEXT double beta decay experiment (1804.00471)

    NEXT Collaboration: P. Novella, B. Palmeiro, A. Simón, M. Sorel, P. Ferrario, G. Martínez-Lema, F. Monrabal, G. Zuzel, J.J. Gómez-Cadenas, C. Adams, V. Álvarez, L. Arazi, C.D.R Azevedo, K. Bailey, J.M. Benlloch-Rodríguez, F.I.G.M. Borges, A. Botas, S. Cárcel, J.V. Carrión, S. Cebrián, C.A.N. Conde, J. Díaz, M. Diesburg, J.M.F. Dos Santos, J. Escada, R. Esteve, R. Felkai, L.M.P. Fernandes, A.L. Ferreira, E.D.C. Freitas, J. Generowicz, A. Goldschmidt, D. González-Díaz, R. Guenette, R.M. Gutiérrez, K. Hafidi, J. Hauptman, C.A.O. Henriques, A.I. Hernandez, J.A. Hernando Morata, V. Herrero, S. Johnston, B.J.P. Jones, M. Kekic, L. Labarga, A. Laing, P. Lebrun, N. López-March, M. Losada, J. Martín-Albo, A. Martínez, A. McDonald, C.M.B. Monteiro, F.J. Mora, J. Muñoz Vidal, M. Musti, M. Nebot-Guinot, D.R. Nygren, A. Para, J. Pérez, M. Querol, J. Renner, J. Repond, S. Riordan, L. Ripoll, J. Rodríguez, L. Rogers, C. Romo, F.P. Santos, C. Sofka, T. Stiegler, J.F. Toledo, J. Torrent, J.F.C.A. Veloso, R. Webb, J.T. White, N. Yahlali
    April 2, 2018 hep-ex, nucl-ex, physics.ins-det
    The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be $(37.5\pm 2.3~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.2~counts/yr in the neutrinoless double beta decay sample.
  • Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier (1707.04794)

    I. Israelashvili, A. E. C. Coimbra, D. Vartsky, L. Arazi, S. Shchemelinin, E. N. Caspi, A. Breskin
    July 15, 2017 physics.ins-det
    Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPM's segmented anode. The localization properties of Co-60 gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12+/-2 mm and 10+/-2 mm (FWHM) were reached with Co-60 and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.
  • In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector (1607.02587)

    L. Moleri, F. D. Amaro, L. Arazi, C. D. R. Azevedo, A. Breskin, A. E. C. Coimbra, E. Oliveri, F. A. Pereira, D. Shaked Renous, J. Schaarschmidt, J. M. F. dos Santos, J. F. C. A. Veloso, S. Bressler
    Sept. 8, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.
  • DARWIN: towards the ultimate dark matter detector (1606.07001)

    J. Aalbers, F. Agostini, M. Alfonsi, F.D. Amaro, C. Amsler, E. Aprile, L. Arazi, F. Arneodo, P. Barrow, L. Baudis, M.L. Benabderrahmane, T. Berger, B. Beskers, A. Breskin, P.A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. Calven, J.M.R. Cardoso, D. Cichon, D. Coderre, A.P. Colijn, J. Conrad, J.P. Cussonneau, M.P. Decowski, S. Diglio, G. Drexlin, E. Duchovni, E. Erdal, G. Eurin, A. Ferella, A. Fieguth, W. Fulgione, A. Gallo Rosso, P. Di Gangi, A. Di Giovanni, M. Galloway, M. Garbini, C. Geis, F. Glueck, L. Grandi, Z. Greene, C. Grignon, C. Hasterok, V. Hannen, E. Hogenbirk, J. Howlett, D. Hilk, C. Hils, A. James, B. Kaminsky, S. Kazama, B. Kilminster, A. Kish, L.M. Krauss, H. Landsman, R.F. Lang, Q. Lin, F.L. Linde, S. Lindemann, M. Lindner, J.A.M. Lopes, T. Marrodan Undagoitia, J. Masbou, F.V. Massoli, D. Mayani, M. Messina, K. Micheneau, A. Molinario, K.D. Mora, E. Morteau, M. Murra, J. Naganoma, J.L. Newstead, K. Ni, U. Oberlack, P. Pakarha, B. Pelssers, P. de Perio, R. Persiani, F. Piastra, M.C. Piro, G. Plante, L. Rauch, S. Reichard, A. Rizzo, N. Rupp, J.M.F. Dos Santos, G. Sartorelli, M. Scheibelhut, S. Schindler, M. Schumann, J. Schreiner, L. Scotto Lavina, M. Selvi, P. Shagin, M.C. Silva, H. Simgen, P. Sissol, M. von Sivers, D. Thers, J. Thurn, A. Tiseni, R. Trotta, C.D. Tunnell, K. Valerius, M.A. Vargas, H. Wang, Y. Wei, C. Weinheimer, T. Wester, J. Wulf, Y. Zhang, T. Zhu, K. Zuber
    June 22, 2016 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
  • Physics reach of the XENON1T dark matter experiment (1512.07501)

    The XENON collaboration: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, L. Arazi, F. Arneodo, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, T. Berger, P. Breur, A. Breskin, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre, A. P. Colijn, J. Conrad, H. Contreras, J. P. Cussonneau, M. P. Decowski, P. de Perio, P. Di Gangi, A. Di Giovanni, E. Duchovni, S. Fattori, A. D. Ferella, A. Fieguth, D. Franco, W. Fulgione, M. Galloway, M. Garbini, C. Geis, L. W. Goetzke, Z. Greene, C. Grignon, E. Gross, W. Hampel, C. Hasterok, R. Itay, F. Kaether, B. Kaminsky, G. Kessler, A. Kish, H. Landsman, R. F. Lang, D. Lellouch, L. Levinson, M. Le Calloch, C. Levy, S. Lindemann, M. Lindner, J. A. M. Lopes, A. Lyashenko, S. Macmullin, A. Manfredini, T. Marrodán Undagoitia, J. Masbou, F. V. Massoli, D. Mayani, A. J. Melgarejo Fernandez, Y. Meng, M. Messina, K. Micheneau, B. Miguez, A. Molinario, M. Murra, J. Naganoma, U. Oberlack, S. E. A. Orrigo, P. Pakarha, B. Pelssers, R. Persiani, F. Piastra, J. Pienaar, G. Plante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, N. Rupp, J. M. F. dos Santos, G. Sartorelli, M. Scheibelhut, S. Schindler, J. Schreiner, M. Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, H. Simgen, A. Stein, D. Thers, A. Tiseni, G. Trinchero, C. Tunnell, M. von Sivers, R. Wall, H. Wang, M. Weber, Y. Wei, C. Weinheimer, J. Wulf, Y. Zhang
    April 15, 2016 physics.ins-det, astro-ph.CO
    ... ... ... ... ... ...
    The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
  • First demonstration of VUV-photon detection in liquid xenon with THGEM and GEM-based Liquid Hole Multipliers (1603.07669)

    E. Erdal, L. Arazi, M. Rappaport, S. Shchemelinin, D. Vartsky, A. Breskin
    March 24, 2016 physics.ins-det, astro-ph.IM
    The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals as they pass into the bubble. In this work we report on recent results of THGEM and GEM electrodes coated with cesium iodide and immersed in liquid xenon, allowing - for the first time - the detection of primary VUV scintillation photons in addition to ionization electrons using LHMs.
  • The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector (1603.04820)

    L. Moleri, F.D. Amaro, L. Arazi, C.D.R. Azevedo, E. Oliveri, M. Pitt, J. Schaarschmidt, D. Shaked-Renous, J.M.F. dos Santos, J.F.C.A. Veloso, A. Breskin, S. Bressler
    March 15, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 10$^9${\Omega}cm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few % when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.
  • First in-beam studies of a Resistive-Plate WELL gaseous multiplier (1510.03116)

    S. Bressler, L. Moleri, M. Pitt, S. Kudella, D. C. R. Azevedo, F. D. Amaro, M. R. Jorge, J. M. F. dos Santos, J. F. C. A. Veloso, H. Natal da Luz, L. Arazi, E. Olivieri, A. Breskin
    Jan. 20, 2016 physics.ins-det
    ... ... ... ... ... ...
    We present the results of the first in-beam studies of a medium size (10$\times$10 cm$^2$) Resistive-Plate WELL (RPWELL): a single-sided THGEM coupled to a pad anode through a resistive layer of high bulk resistivity ($\sim$10$^9 \Omega$cm). The 6.2~mm thick (excluding readout electronics) single-stage detector was studied with 150~GeV muons and pions. Signals were recorded from 1$\times$1 cm$^2$ square copper pads with APV25-SRS readout electronics. The single-element detector was operated in Ne\(5% $\mathrm{CH_{4}}$) at a gas gain of a few times 10$^4$, reaching 99$\%$ detection efficiency at average pad multiplicity of $\sim$1.2. Operation at particle fluxes up to $\sim$10$^4$ Hz/cm$^2$ resulted in $\sim$23$\%$ gain drop leading to $\sim$5$\%$ efficiency loss. The striking feature was the discharge-free operation, also in intense pion beams. These results pave the way towards robust, efficient large-scale detectors for applications requiring economic solutions at moderate spatial and energy resolutions.
  • Direct observation of bubble-assisted electroluminescence in liquid xenon (1509.02354)

    E. Erdal, L. Arazi, V. Chepel, M. L. Rappaport, D. Vartsky, A. Breskin
    Sept. 8, 2015 physics.ins-det
    Bubble formation in liquid xenon underneath a Thick Gaseous Electron Multiplier (THGEM) electrode immersed in liquid xenon was observed with a CCD camera. With voltage across the THGEM, the appearance of bubbles was correlated with that of electroluminescence signals induced by ionization electrons from alpha-particle tracks. This confirms recent indirect evidence that the observed photons are due to electroluminescence within a xenon vapor layer trapped under the electrode. The bubbles seem to emerge spontaneously due to heat flow from 300K into the liquid, or in a controlled manner, by locally boiling the liquid with resistive wires. Controlled bubble formation resulted in energy resolution of {\sigma}/E~7.5% for ~6,000 ionization electrons. The phenomenon could pave ways towards the conception of large-volume 'local dual-phase' noble-liquid TPCs.
  • First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC (1508.00410)

    L. Arazi, A. E. C. Coimbra, E. Erdal, I. Israelashvili, M. L. Rappaport, S. Shchemelinin, D. Vartsky, J. M. F. dos Santos, A. Breskin
    Aug. 3, 2015 physics.ins-det
    We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a dual-phase liquid xenon (LXe) TPC, demonstrating - for the first time - the feasibility of recording both primary ("S1") and secondary ("S2") scintillation signals. The detector comprised a triple Thick Gas Electron Multiplier (THGEM) structure with cesium iodide photocathode on the first element; it was shown to operate stably at 180 K with gains above 10^5, providing high single-photon detection efficiency even in the presence of large alpha particle-induced S2 signals comprising thousands of photoelectrons. S1 scintillation signals were recorded with a time resolution of 1.2 ns (RMS). The energy resolution ({\sigma}/E) for S2 electroluminescence of 5.5 MeV alpha particles was ~9%, which is comparable to that obtained in the XENON100 TPC with PMTs. The results are discussed within the context of potential GPM deployment in future multi-ton noble-liquid detectors.
  • Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data (1507.07747)

    The XENON Collaboration: E. Aprile, F. Agostini, M. Alfonsi, L. Arazi, K. Arisaka, F. Arneodo, M. Auger, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, A. Behrens, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. M. R. Cardoso, M. Cervantes, D. Coderre, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, A. Di Giovanni, E. Duchovni, S. Fattori, A. D. Ferella, A. Fieguth, W. Fulgione, F. Gao, M. Garbini, C. Geis, L. W. Goetzke, C. Grignon, E. Gross, W. Hampel, R. Itay, F. Kaether, B. Kaminsky, G. Kessler, A. Kish, H. Landsman, R. F. Lang, M. Le Calloch, D. Lellouch, L. Levinson, C. Levy, S. Lindemann, M. Lindner, J. A. M. Lopes, A. Lyashenko, S. Macmullin, T. Marrodan Undagoitia, J. Masbou, F. V. Massoli, D. Mayani Paras, A. J. Melgarejo Fernandez, Y. Meng, M. Messina, B. Miguez, A. Molinario, G. Morana, M. Murra, J. Naganoma, K. Ni, U. Oberlack, S. E. A. Orrigo, P. Pakarha, E. Pantic, R. Persiani, F. Piastra, J. Pienaar, G. Plante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, J. M. F. dos Santos, G. Sartorelli, S. Schindler, J. Schreiner, M. Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, H. Simgen, A. Teymourian, D. Thers, A. Tiseni, G. Trinchero, C. Tunnell, O. Vitells, R. Wall, H. Wang, M. Weber, C. Weinheimer
    July 28, 2015 hep-ex, astro-ph.CO
    ... ... ... ... ... ...
    Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
  • Search for Event Rate Modulation in XENON100 Electronic Recoil Data (1507.07748)

    The XENON Collaboration: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, M. Anthony, L. Arazi, K. Arisaka, F. Arneodo, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. M. R. Cardoso, M. Cervantes, D. Coderre, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, P. de Perio, A. Di Giovanni, E. Duchovni, S. Fattori, A. D. Ferella, A. Fieguth, W. Fulgione, F. Gao, M. Garbini, C. Geis, L. W. Goetzke, C. Grignon, E. Gross, W. Hampel, C. Hasterok, R. Itay, F. Kaether, B. Kaminsky, G. Kessler, A. Kish, H. Landsman, R. F. Lang, M. Le Calloch, D. Lellouch, L. Levinson, C. Levy, S. Lindemann, M. Lindner, J. A. M. Lopes, A. Lyashenko, S. Macmullin, T. Marrodan Undagoitia, J. Masbou, F. V. Massoli, D. Mayani, A. J. Melgarejo Fernandez. Y. Meng, M. Messina, K. Micheneau, B. Miguez, A. Molinario, M. Murra, J. Naganoma, K. Ni, U. Oberlack, S. E. A. Orrigo, P. Pakarha, R. Persiani, F. Piastra, J. Pienaar, G. Plante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, J. M. F. dos Santos, G. Sartorelli, S. Schindler, J. Schreiner, M. Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, H. Simgen, A. Teymourian, D. Thers, A. Tiseni, G. Trinchero, C. Tunnell, R. Wall, H. Wang, M. Weber, C. Weinheimer, Y. Zhang
    July 28, 2015 hep-ex, physics.ins-det, astro-ph.CO
    ... ... ... ... ... ...
    We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
  • Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon (1505.02316)

    L. Arazi, E. Erdal, A. E. C. Coimbra, M. L. Rappaport, D. Vartsky, V. Chepel, A. Breskin
    May 13, 2015 hep-ex, physics.ins-det, astro-ph.IM
    In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of operation, providing - under specific thermodynamic conditions - energy resolution similar to that of present dual-phase liquid xenon experiments. The observed mechanism may serve as the basis for the development of Liquid Hole Multipliers (LHMs), capable of producing local charge-induced electroluminescence signals in large-volume single-phase noble-liquid detectors for dark matter and neutrino physics experiments.
  • Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment (1503.07698)

    E. Aprile, F. Agostini, M. Alfonsi, L. Arazi, K. Arisaka, F. Arneodo, M. Auger, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. M. R. Cardoso, D. Coderre, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowksi, A. Di Giovanni, E. Duchovni, S. Fattori, A. D. Ferella, A. Fieguth, W. Fulgione, M. Garbini, C. Geis, L. W. Goetzke, C. Grignon, E. Gross, W. Hampel, R. Itay, F. Kaether, G. Kessler, A. Kish, H. Landsman, R. F. Lang, M. Le Calloch, D. Lellouch, L. Levinson, C. Levy, S. Lindemann, M. Lindner, J. A. M. Lopes, A. Lyashenko, S. Macmullin, T. Marrodan Undagoitia, J. Masbou, F. V. Massoli, D. Mayani, A. J. Melgarejo Fernandez, Y. Meng, M. Messina, B. Miguez, A. Molinario, G. Morana, M. Murra, J. Naganoma, U. Oberlack, S. E. A. Orrigo, P. Pakarha, E. Pantic, R. Persiani, F. Piastra, J. Pienaar, G. Plante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, J. M. F. dos Santos, G. Sartorelli, S. Schindler, J. Schreiner, M. Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, H. Simgen, A. Teymourian, D. Thers, A. Tiseni, G. Trinchero, C. Tunnell, O. Vitells, R. Wall, H. Wang, M. Weber, C. Weinheimer, , M. Laubenstein
    March 26, 2015 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
  • A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection (1501.00150)

    I. Israelashvili, M. Cortesi, D. Vartsky, L. Arazi, D. Bar, E. N. Caspi, A. Breskin
    Dec. 31, 2014 physics.ins-det
    Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the type and performance of LXe converter. We have evaluated the detector spectral response, detection efficiency and spatial resolution for gamma-rays and neutrons in the energy range of 2-15 MeV for 50 mm thick converters consisting of plain LXe volume and LXe-filled capillaries, of Teflon, Polyethylene or hydrogen-containing Teflon (Tefzel). Neutron detection efficiencies for plain LXe, Teflon-capillaries and Tefzel-capillaries converters were about 20% over the entire energy range. In polyethylene capillaries converters the neutron detection efficiency was about 10% at 2 MeV and increased up to about 20% at 14 MeV. Detection efficiencies of gammas in Teflon, Tefzel and polyethylene converters were ~35%. The plain-LXe converter provided the highest gamma-ray detection efficiency, of ~40-50% for 2-15 MeV energy range. Optimization of LXe-filled Tefzel capillary dimensions resulted in spatial resolution of ~1.5mm (FWHM) for neutrons and up to 3.5 mm (FWHM) for gamma-rays. Simulations of radiographic images of various materials using two discrete energy gamma-rays (4.4 MeV and 15.1 MeV) and neutrons in broad energy range (2-10 MeV) were performed in order to evaluate the potential of elemental discrimination.
  • Optical readout: a tool for studying gas-avalanche processes (1305.1196)

    A. Rubin, L. Arazi, S. Bressler, A. Dery, L. Moleri, M. Pitt, D. Vartsky, A. Breskin
    Jan. 5, 2014 physics.ins-det
    Optical recording of avalanche-induced photons is an interesting tool for studying basic physics processes in gaseous detectors. In this work we demonstrate the potential of optical readout in avalanche-propagation investigations in Thick Gas Electron Multipliers (THGEMs) operated with Ne/CF4 (95/5). We present the results of direct measurements, with single- and cascaded-THGEM detectors irradiated with soft x-rays, of the hole-multiplicity and avalanche asymmetry within holes, as a function of detector parameters. Further study directions are discussed.
  • A concept for laboratory studies of radiation detectors over a broad dynamic-range: instabilities evaluation in THGEM-structures (1311.0340)

    S. Bressler, L. Moleri, L. Arazi, E. Erdal, A. Rubin, M. Pitt, A. Breskin
    Nov. 5, 2013 physics.ins-det
    ... ... ... ... ... ...
    A simple methodology for evaluating the dynamic-range of gas avalanche detectors in the laboratory is presented and discussed. It comprises two tools: a charge injector of tunable gain which transfers radiation-induced amplified electron swarms to the investigated detector to mimic events with well defined primary-ionization spectra, and a systematic approach for measuring the detector's discharge probability. The methodology, applicable to a broad range of detectors, is applied here for instability studies in various single-stage THGEM and THGEM-WELL structures. The results indicate upon a somewhat larger attainable dynamic range in a single-stage THGEM operated with additional multiplication in the induction gap.
  • Laboratory studies of THGEM-based WELL structures with resistive anodes (1310.6183)

    L. Arazi, M. Pitt, S. Bressler, L. Moleri, A. Rubin, A. Breskin
    Oct. 23, 2013 physics.ins-det
    In this work we investigate three variants of single amplification-stage detector elements; they comprise THGEM electrodes closed at their bottom with metallic or resistive anodes to form WELL-type configurations. We present the results of a comparative study of the Thick-WELL (THWELL), Resistive-WELL (RWELL) and Segmented Resistive WELL (SRWELL), focusing on their performance in terms of spark-quenching capability, gain variation with position and counting rate, pulse shapes and signal propagation to neighboring readout pads; the study included both 30x30 and 100x100 mm$^2$ detectors. It was shown that the WELL structures with resistive anodes offer stable operation even in a highly ionizing environment, with effective spark quenching, as well as higher gain than the standard THGEM/induction-gap configuration. Cross talk between neighboring readout pads was shown to be effectively eliminated in the segmented detector with a conductive grid underneath the resistive layer. The latter multiplier should allow for the design of very thin detectors, e.g. sampling elements in digital hadronic calorimeters planned for experiments in future linear colliders.
  • Recent advances with THGEM detectors (1310.3912)

    S. Bressler, L. Arazi, L. Moleri, M. Pitt, A. Rubin, A. Breskin
    Oct. 15, 2013 physics.ins-det
    The Thick Gaseous Electron Multiplier (THGEM) is a simple and robust electrode suitable for large area detectors. In this work the results of extensive comparative studies of the physical properties of different THGEM-based structures are reviewed. The focus is on newly suggested THGEM-like WELL configurations as well as on recently developed characterization methods. The WELL structures are single-sided THGEM electrodes directly coupled to different anode readout electrodes. The structures differ by the coupling concept of the bottom THGEM electrode to the metallic readout pads: a Thick WELL (THWELL) with direct coupling; the Resistive WELL (RWELL) and the Segmented Resistive WELL (SRWELL) coupled through thin resistive films deposited on insulating sheets and a Resistive-Plate WELL (RPWELL) coupled through a plate of high bulk resistivity. The results are compared to that of traditional double-sided THGEM electrodes followed by induction gaps - in some cases with moderate additional multiplication within the gap. We compare the different configurations in terms of gain, avalanche extension, discharge-rate and magnitude as well as rate capabilities over a broad dynamic range - exploiting a method that mimics highly ionizing particles in the laboratory. We report on recent studies of avalanche distribution in THGEM holes using optical readout.
  • First observation of liquid-xenon proportional electroluminescence in THGEM holes (1310.4074)

    L. Arazi, A. E. C. Coimbra, R. Itay, H. Landsman, L. Levinson, M. L. Rappaport, D. Vartsky, A. Breskin
    Oct. 15, 2013 physics.ins-det
    Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were observed using a 0.4 mm thick electrode with 0.3 mm diameter holes; at 2 kV across the THGEM the photon yield was estimated to be ~600 UV photons/electron over 4pi This may pave the way towards the realization of novel single-phase noble-liquid radiation detectors incorporating liquid hole-multipliers (LHM); their concept is presented.
  • First studies with the Resistive-Plate WELL gaseous multiplier (1308.6152)

    A. Rubin, L. Arazi, S. Bressler, L. Moleri, M. Pitt, A. Breskin
    Aug. 28, 2013 physics.ins-det
    ... ... ... ... ... ...
    We present the results of first studies of the Resistive Plate WELL (RPWELL): a single-faced THGEM coupled to a copper anode via a resistive layer of high bulk resistivity. We explored various materials of different bulk resistivity (10^9 - 10^12 Ohm cm) and thickness (0.4 - 4 mm). Our most successful prototype, with a 0.6 mm resistive plate of ~10^9 Ohm cm, achieved gains of up to 10^5 with 8 keV x-ray in Ne/5%CH4; a minor 30% gain drop occurred with a rate increase from 10 to 10^4 Hz/mm^2. The detector displayed a full "discharge-free" operation--even when exposed to high primary ionization events. We present the RPWELL detector concept and compare its performance to that of other previously explored THGEM configurations--in terms of gain, its curves, dependence on rate, and the response to high ionization. The robust Resistive Plate WELL concept is a step forward in the Micro-Pattern Gas-Detector family, with numerous potential applications.