• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Run 2 Upgrades to the CMS Level-1 Calorimeter Trigger (1511.05855)

    B. Kreis, J. Berryhill, R. Cavanaugh, K. Mishra, R. Rivera, L. Uplegger, L. Apanasevich, J. Zhang, J. Marrouche, N. Wardle, R. Aggleton, F. Ball, J. Brooke, D. Newbold, S. Paramesvaran, D. Smith, M. Baber, A. Bundock, M. Citron, A. Elwood, G. Hall, G. Iles, C. Laner, B. Penning, A. Rose, A. Tapper, C. Foudas, F. Beaudette, L. Cadamuro, L. Mastrolorenzo, T. Romanteau, J. B. Sauvan, T. Strebler, A. Zabi, R. Barbieri, I. A. Cali, G. M. Innocenti, Y.-J. Lee, C. Roland, B. Wyslouch, M. Guilbaud, W. Li, M. Northup, B. Tran, T. Durkin, K. Harder, S. Harper, C. Shepherd-Themistocleous, A. Thea, T. Williams, M. Cepeda, S. Dasu, L. Dodd, R. Forbes, T. Gorski, P. Klabbers, A. Levine, I. Ojalvo, T. Ruggles, N. Smith, W. Smith, A. Svetek, J. Tikalsky, M. Vicente
    Nov. 18, 2015 hep-ex, physics.ins-det
    The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.
  • Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube (1403.3215)

    L. Cadamuro, M.Calvi, L. Cassina, A. Giachero, C. Gotti, B. Khanji, M. Maino, C. Matteuzzi, G. Pessina
    March 13, 2014 hep-ex, physics.ins-det
    The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage dividers have been tested. The results of a standard characterization of the gain and the anode uniformity, the dark signal rate, the cross-talk and the device behaviour as a function of temperature have been studied. The behaviour of the tube is studied in a longitudinal magnetic field up to 100 Gauss. Shields made of a high permeability material are also investigated. The deterioration of the device performance due to long time operation at intense light exposure is studied. A quantitative analysis of the variation of the gain and the dark signals rate due to the aging is described.