• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout (1301.4817)

    A.Badertscher, A.Curioni, U.Degunda, L.Epprecht, A.Gendotti, S.Horikawa, L.Knecht, D.Lussi G.Natterer, K.Nguyen, F.Resnati, A.Rubbia, T.Viant
    Jan. 21, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the readout consists of a $40\times 76$ cm$^2$ LEM and 2D projective anode to multiply and collect drifting charges. Scintillation light is detected by means of cryogenic PMTs positioned below the cathode. To record both charge and light signals, we have developed a compact acquisition system, which is scalable up to ton-scale detectors with thousands of charge readout channels. The acquisition system, as well as the design and the performance of custom-made charge sensitive preamplifiers, are described. The complete experimental setup has been operated for a first time during a period of four weeks at CERN in the cryostat of the ArDM experiment, which was equipped with liquid and gas argon purification systems. The detector, exposed to cosmic rays, recorded events with a single-channel signal-to-noise ratio in excess of 30 for minimum ionising particles. Cosmic muon tracks and their $\delta$-rays were used to assess the performance of the detector, and to estimate the liquid argon purity and the gain at different amplification fields.
  • A tagged low-momentum kaon test-beam exposure with a 250L LAr TPC (J-PARC T32) (1105.5818)

    O. Araoka, A.Badertscher, A.Curioni, S.DiLuise, U.Degunda, L.Epprecht, L.Esposito, A.Gendotti, T.Hasegawa, S.Horikawa, K.Kasami, N.Kimura, L.Knecht, T.Kobayashi, C.Lazzaro, D.Lussi, M.Maki, A.Marchionni, T.Maruyama, A.Meregaglia, T.Mitani, Y.Nagasaka, J.Naganoma, H.Naito, S.Narita, G.Natterer, K.Nishikawa, A.Okamoto, H.Okamoto, F.Petrolo, F.Resnati, A.Rubbia, C.Strabel, M.Tanaka, T.Viant, Y.Yamanoi, K.Yorita, M.Yoshioka
    May 29, 2011 physics.ins-det
    ... ... ... ... ... ...
    At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the neutrino sector and to search for nucleon decay. As a first step we proposed a test experiment to identify and measure charged kaons, including their decays, in liquid argon. The detector, a 250L LAr TPC, is exposed to charged kaons, in a momentum range of 540-800 MeV/c, in the K1.1BR beamline of the J-PARC slow extraction facility. This is especially important to estimate efficiency and background for nucleon decay searches in the charged kaon mode ($p \rightarrow \bar{\nu} K^+$, etc.), where the kaon momentum is expected to be in the few hundred MeV/c range. A prototype setup has been exposed in the K1.1BR beamline in the fall of 2010. This paper describes the capabilities of the beamline, the construction and setting up of the detector prototype, along with some preliminary results.
  • Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen (1010.5811)

    A.Badertscher, L.Knecht, M.Laffranchi, G.Natterer, A.Rubbia, Th.Strauss
    Oct. 27, 2010 physics.ins-det
    ... ... ... ... ... ...
    Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical current $I_c$ of HTS cables in an external magnetic field was measured at liquid nitrogen and liquid argon temperatures and a small prototype HTS solenoid was built and tested.
  • First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches (1009.3641)

    C. Amsler, A. Badertscher, V.Boccone, A.Bueno, M.C.Carmona-Benitez, W.Creus, A.Curioni, M.Daniel, E.J.Dawe, U.Degunda, A.Gendotti, L.Epprecht, S.Horikawa, L.Kaufmann, L.Knecht, M.Laffranchi, C.Lazzaro, P.K.Lightfoot, D.Lussi, J.Lozano, A.Marchionni, K.Mavrokoridis, A.Melgarejo, P.Mijakowski, G.Natterer, S.Navas-Concha, P.Otyugova, M.dePrado, P.Przewlocki, C.Regenfus, F.Resnati, M.Robinson, J.Rochet, L.Romero, E.Rondio, A.Rubbia, L.Scotto-Lavina, N.J.C.Spooner, T.Strauss, J.Ulbricht, T.Viant (The ArDM Collaboration)
    Oct. 27, 2010 physics.ins-det
    ... ... ... ... ... ...
    ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. The goal is to reach a minimum recoil energy of 30\,keVr to detect recoiling nuclei. In this paper we describe the experimental concept and present results on the light detection system, tested for the first time in ArDM on the surface at CERN. With a preliminary and incomplete set of PMTs, the light yield at zero electric field is found to be between 0.3-0.5 phe/keVee depending on the position within the detector volume, confirming our expectations based on smaller detector setups.
  • Stable operation with gain of a double phase Liquid Argon LEM-TPC with a 1 mm thick segmented LEM (1010.2482)

    A.Badertscher, A.Curioni, S.Horikawa, L.Knecht, D.Lussi, A.Marchionni, G.Natterer, F.Resnati, A.Rubbia, T.Viant
    Oct. 12, 2010 physics.ins-det
    ... ... ... ... ... ...
    In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification, suited for next-generation neutrino detectors and possibly direct Dark Matter searches. During a test of a 3~lt chamber equipped with a 10$\times$10~cm$^2$ readout, cosmic muon data was recorded during three weeks of data taking. A maximum gain of 6.5 was achieved and the liquid argon was kept pure enough to ensure 20~cm drift (O(ppb)~O$_2$ equivalent).
  • The ArDM experiment (1006.5335)

    ArDM Collaboration: C.Amsler, A.Badertscher, V.Boccone, N.Bourgeois, A.Bueno, M.C.Carmona-Benitez, M.Chorowski, W.Creus, A.Curioni, E.Daw, U.Degunda, A.Dell'Antone, M.Droge, L.Epprecht, C.Haller, M.Haranczyk, S.Horikawa, L.Kaufmann, J.Kisiel, L.Knecht, M.Laffranchi, J.Lagoda, C.Lazzaro, P.Lightfoot, J.Lozano, D.Lussi, G.Maire, S.Mania, A.Marchionni, K.Mavrokoridis, A.Melgarejo, P.Mijakowski, G.Natterer, S.Navas-Concha, P.Otiougova, A.Piotrowska, J.Polinski, M.de Prado, P.Przewlocki, S.Ravat, C.Regenfus, F.Resnati, M.Robinson, J.Rochet, L.Romero, E.Rondio, A.Rubbia, L.Scotto-Lavina, N.Spooner, T.Viant, A.Trawinski, J.Ulbricht, A.Zalewska
    June 28, 2010 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
  • Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: comparison of single and double phase operation (0907.2944)

    A.Badertscher, L.Knecht, M.Laffranchi, D.Lussi, A.Marchionni, G.Natterer, P.Otiougova, F.Resnati, A.Rubbia, T.Viant
    July 16, 2009 physics.ins-det
    ... ... ... ... ... ...
    We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole electron multiplier built with standard PCB techniques: drifting electrons are extracted from the liquid to the vapour phase and driven into the holes of the LEM where the multiplication occurs. Moving charges induce a signal on the anode and on the LEM electrodes. The orthogonally segmented upper face of the upper LEM and anode permit the reconstruction of X-Y spatial coordinates of ionizing events. The detector is equipped with a Photo Multiplier Tube immersed in liquid for triggering the ionizing events and an argon purification circuit to ensure long drift paths. Cosmic muon tracks have been recorded and further characterization of the detector is ongoing. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.
  • Development of wavelength shifter coated reflectors for the ArDM argon dark matter detector (0904.0246)

    The ArDM Collaboration: V. Boccone, P.K.Lightfoot, K.Mavrokoridis, C.Regenfus, C.Amsler, A.Badertscher, A.Bueno, H.Cabrera, M.C.Carmona-Benitez, M.Daniel, E.J.Daw, U.Degunda, A.Dell'Antone, A.Gendotti, L.Epprecht, S.Horikawa, L.Kaufmann, L.Knecht, M.Laffranchi, C.Lazzaro, D.Lussi, J.Lozano, A.Marchionni, A.Melgarejo, P.Mijakowski, G.Natterer, S.Navas-Concha, P.Otyugova, M. de Prado, P.Przewlocki, F.Resnati, M.Robinson, J.Rochet, L.Romero, E.Rondio, A.Rubbia, N.J.C.Spooner, T.Strauss, J.Ulbricht, T.Viant
    April 1, 2009 physics.ins-det
    ... ... ... ... ... ...
    To optimise the design of the light readout in the ArDM 1-ton liquid argon dark matter detector, a range of reflector and WLS coating combinations were investigated in several small setups, where argon scintillation light was generated by radioactive sources in gas at normal temperature and pressure and shifted into the blue region by tetraphenyl butadiene (TPB). Various thicknesses of TPB were deposited by spraying and vacuum evaporation onto specular 3M{\small\texttrademark}-foil and diffuse Tetratex{\small\textregistered} (TTX) substrates. Light yields of each reflector and TPB coating combination were compared. Reflection coefficients of TPB coated reflectors were independently measured using a spectroradiometer in a wavelength range between 200 and 650 nm. WLS coating on the PMT window was also studied. These measurements were used to define the parameters of the light reflectors of the ArDM experiment. Fifteen large $120\times 25$ cm$^2$ TTX sheets were coated and assembled in the detector. Measurements in argon gas are reported providing good evidence of fulfilling the light collection requirements of the experiment.
  • Construction and operation of a Double Phase LAr Large Electron Multiplier Time Projection Chamber (0811.3384)

    A.Badertscher, L.Knecht, M.Laffranchi, A.Marchionni, G.Natterer, P.Otiougova, F.Resnati, A.Rubbia
    Nov. 20, 2008 physics.ins-det
    ... ... ... ... ... ...
    We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where charge amplification occurs. Each LEM is a thick macroscopic hole multiplier of 10x10 cm$^2$ manufactured with standard PCB techniques. The electrons signal is readout via two orthogonal coordinates, one using the induced signal on the segmented upper electrode of the LEM itself and the other by collecting the electrons on a segmented anode. Custom-made preamplifiers have been especially developed for this purpose. Cosmic ray tracks have been successfully observed in pure gas at room temperature and in double phase Ar operation. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.