GRAVITY is a new instrument to coherently combine the light of the European
Southern Observatory Very Large Telescope Interferometer to form a telescope
with an equivalent 130 m diameter angular resolution and a collecting area of
200 m$^2$. The instrument comprises fiber fed integrated optics beam
combination, high resolution spectroscopy, built-in beam analysis and control,
near-infrared wavefront sensing, phase-tracking, dual beam operation and laser
metrology [...]. This article gives an overview of GRAVITY and reports on the
performance and the first astronomical observations during commissioning in
2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag,
phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a
limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a
visibility accuracy of better than 0.25 %, and spectro-differential phase and
closure phase accuracy better than 0.5{\deg}, corresponding to a differential
astrometric precision of better than 10 microarcseconds ({\mu}as). The
dual-beam astrometry, measuring the phase difference of two objects with laser
metrology, is still under commissioning. First observations show residuals as
low as 50 {\mu}as when following objects over several months. We illustrate the
instrument performance with the observations of archetypical objects for the
different instrument modes. Examples include the Galactic Center supermassive
black hole and its fast orbiting star S2 for phase referenced dual beam
observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru
and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential
astrometry, the T Tauri star S CrA for a spectro-differential visibility
analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and
{\eta} Car for interferometric imaging with GRAVITY.
-
The visitor instrument PIONIER provides VLTI with improved imaging
capabilities and sensitivity. The instrument started routinely delivering
scientific data in November 2010, that is less than 12 months after being
approved by the ESO Science and Technical Committee. We recall the challenges
that had to be tackled to design, built and commission PIONIER. We summarize
the typical performances and some astrophysical results obtained so far. We
conclude this paper by summarizing lessons learned.
-
X-shooter is the first 2nd generation instrument of the ESO Very Large
Telescope(VLT). It is a very efficient, single-target, intermediate-resolution
spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The
instrument covers, in a single exposure, the spectral range from 300 to 2500
nm. It is designed to maximize the sensitivity in this spectral range through
dichroic splitting in three arms with optimized optics, coatings, dispersive
elements and detectors. It operates at intermediate spectral resolution
(R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle
spectral format (prism cross-dispersers) in the three arms. It includes a
1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A
dedicated data reduction package delivers fully calibrated two-dimensional and
extracted spectra over the full wavelength range. We describe the main
characteristics of the instrument and present its performance as measured
during commissioning, science verification and the first months of science
operations.
-
PIONIER stands for Precision Integrated-Optics Near-infrared Imaging
ExpeRiment. It combines four 1.8m Auxilliary Telescopes or four 8m Unit
Telescopes of the Very Large Telescope Interferometer (ESO, Chile) using an
integrated optics combiner. The instrument has been integrated at IPAG starting
in December 2009 and commissioned at the Paranal Observatory in October 2010.
It provides scientific observations since November 2010. In this paper, we
detail the instrumental concept, we describe the standard operational modes and
the data reduction strategy. We present the typical performance and discuss how
to improve them. This paper is based on laboratory data obtained during the
integrations at IPAG, as well as on-sky data gathered during the commissioning
at VLTI. We illustrate the imaging capability of PIONIER on the binaries
deltaSco and HIP11231. PIONIER provides 6 visibilities and 3 independent
closure phases in the H band, either in a broadband mode or with a low spectral
dispersion (R=40), using natural light (i.e. unpolarized). The limiting
magnitude is Hmag=7 in dispersed mode under median atmospheric conditions
(seeing<1", tau0>3ms) with the 1.8m Auxiliary Telescopes. We demonstrate a
precision of 0.5deg on the closure phases. The precision on the calibrated
visibilities ranges from 3 to 15% depending on the atmospheric conditions.
PIONIER has been installed and successfully tested as a visitor instrument for
the VLTI. It permits high angular resolution imaging studies at an
unprecedented level of sensitivity. The successful combination of the four 8m
Unit Telescopes in March 2011 demonstrates that VLTI is ready for 4-telescope
operation.
-
PIONIER is a 4-telescope visitor instrument for the VLTI, planned to see its
first fringes in 2010. It combines four ATs or four UTs using a pairwise ABCD
integrated optics combiner that can also be used in scanning mode. It provides
low spectral resolution in H and K band. PIONIER is designed for imaging with a
specific emphasis on fast fringe recording to allow closure-phases and
visibilities to be precisely measured. In this work we provide the detailed
description of the instrument and present its updated status.
-
In this work, we present the first AMBER observations, of the Wolf-Rayet and
O (WR+O) star binary system y2 Velorum. The AMBER instrument was used with the
telescopes UT2, UT3, and UT4 on baselines ranging from 46m to 85m. It delivered
spectrally dispersed visibilities, as well as differential and closure phases,
with a resolution R = 1500 in the spectral band 1.95-2.17 micron. We interpret
these data in the context of a binary system with unresolved components,
neglecting in a first approximation the wind-wind collision zone flux
contribution. We show that the AMBER observables result primarily from the
contribution of the individual components of the WR+O binary system. We discuss
several interpretations of the residuals, and speculate on the detection of an
additional continuum component, originating from the free-free emission
associated with the wind-wind collision zone (WWCZ), and contributing at most
to the observed K-band flux at the 5% level. The expected absolute separation
and position angle at the time of observations were 5.1±0.9mas and
66±15° respectively. However, we infer a separation of
3.62+0.11-0.30 mas and a position angle of 73+9-11°. Our analysis thus
implies that the binary system lies at a distance of 368+38-13 pc, in agreement
with recent spectrophotometric estimates, but significantly larger than the
Hipparcos value of 258+41-31 pc.