-
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began
operation at the Laboratori Nazionali del Gran Sasso in Italy. The array
represents a significant advancement in this technology, and in this work we
apply it for the first time to a high-sensitivity search for a
lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay.
Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an
effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the
region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we
find no evidence for neutrinoless double-beta decay. The median statistical
sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic
uncertainties, we place a lower limit on the decay half-life of
$T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining
this result with those of two earlier experiments, Cuoricino and CUORE-0, we
find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is
the most stringent limit to date on this decay. Interpreting this result as a
limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 -
520)$ meV, where the range reflects the nuclear matrix element estimates
employed.
-
We report the results of a search for neutrinoless double-beta decay in a
9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm
0.004\,(\mathrm{stat.})\pm
0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times
10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of $^{130}$Te and place a
Bayesian lower bound on the decay half-life, $T^{0\nu}_{1/2}>$~$ 2.7\times
10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr
exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0\nu}_{1/2}
> 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
$m_{\beta\beta}< 270$ -- $760~\mathrm{meV}$.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is an
experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in
$^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of
988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being
constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will
start taking data in 2015. If the target background of 0.01
counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking
CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\%
C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to
test and demonstrate the performances expected for CUORE, has been assembled
and is running. The detector is a single tower of 52 CUORE-like bolometers that
started taking data in spring 2013. The status and perspectives of CUORE will
be discussed, and the first CUORE-0 data will be presented.
-
Neutrinoless double-beta ($0\nu\beta\beta$) decay is a hypothesized
lepton-number-violating process that offers the only known means of asserting
the possible Majorana nature of neutrino mass. The Cryogenic Underground
Observatory for Rare Events (CUORE) is an upcoming experiment designed to
search for $0\nu\beta\beta$ decay of $^{130}$Te using an array of 988 TeO$_2$
crystal bolometers operated at 10 mK. The detector will contain 206 kg of
$^{130}$Te and have an average energy resolution of 5 keV; the projected
$0\nu\beta\beta$ decay half-life sensitivity after five years of live time is
$1.6\times 10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence
level), which corresponds to an upper limit on the effective Majorana mass in
the range 40--100 meV (50--130 meV). In this paper we review the experimental
techniques used in CUORE as well as its current status and anticipated physics
reach.
-
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless
double beta decay of 130Te. The detector is being constructed at the Laboratori
Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If
the target background of 0.01 counts/keV/kg/y will be reached, in five years of
data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0
is a smaller experiment constructed to test and demonstrate the performances
expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers
that started taking data in spring 2013. The status and perspectives of CUORE
will be discussed, and the first CUORE-0 data will be presented.
-
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.
-
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide
bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present
the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on
background measurements and energy resolution. The background rates in the
neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the
{\alpha} background-dominated region (2.70 to 3.90 MeV) have been measured to
be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The
latter result represents a factor of 6 improvement from a predecessor
experiment, Cuoricino. The results verify our understanding of the background
sources in CUORE-0, which is the basis of extrapolations to the full CUORE
detector. The obtained energy resolution (full width at half maximum) in the
region of interest is 5.7 keV. Based on the measured background rate and energy
resolution in the region of interest, CUORE-0 half-life sensitivity is expected
to surpass the observed lower bound of Cuoricino with one year of live time.
-
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y
at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with $^{130}$Te and possibly other double beta decay candidate nuclei.
-
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.
-
We report the results of a search for axions from the 14.4 keV M1 transition
from Fe-57 in the core of the sun using the axio-electric effect in TeO2
bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a
facility used to test bolometers for the CUORE experiment at the Laboratori
Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made
using a newly developed low energy trigger which was optimized to reduce the
detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established
at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the
Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the
flavor-singlet axial vector matrix element. Bounds are given for the interval
0.15 < S < 0.55.
-
In this article we describe the background challenges for the CUORE
experiment posed by surface contamination of inert detector materials such as
copper, and present three techniques explored to mitigate these backgrounds.
Using data from a dedicated test apparatus constructed to validate and compare
these techniques we demonstrate that copper surface contamination levels better
than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels
are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit
on the number of background counts in the region of interest is 0.02-0.03
counts/keV/kg/y depending on the adopted mitigation technique.
-
We present a study of the sensitivity and discovery potential of CUORE, a
bolometric double-beta decay experiment under construction at the Laboratori
Nazionali del Gran Sasso in Italy. Two approaches to the computation of
experimental sensitivity for various background scenarios are presented, and an
extension of the sensitivity formulation to the discovery potential case is
also discussed. Assuming a background rate of 10^-2 cts/(keV kg y), we find
that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the
neutrinoless double-beta decay half-life of T_1/2(1 sigma) = 1.6 \times 10^26 y
and thus a potential to probe the effective Majorana neutrino mass down to
40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will
be T_1/2(1.64 sigma) = 9.5 \times 10^25 y. This range is compared with the
claim of observation of neutrinoless double-beta decay in 76Ge and the
preferred range of the neutrino mass parameter space from oscillation results.
-
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.
-
The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal
bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished
in 2008 after more than 3 years of active operating time. Searches for both
$0\nu$ and $2\nu$ double-beta decay to the first excited $0^{+}$ state in
$^{130}$Xe were performed by studying different coincidence scenarios. The
analysis was based on data representing a total exposure of
N($^{130}$Te)$\cdot$t=$9.5\times10^{25}\,$y. No evidence for a signal was
found. The resulting lower limits on the half lives are $T^{2\nu}_{1/2}(^{130}
Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,$y (90% C.L.), and
$T^{0\nu}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,$y (90%
C.L.).
-
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end
of 2008 at the Gran Sasso National Laboratories, in order to test the
performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS
(Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE
experiment. In this work the results of the first 5 validation runs are
presented. Results have been obtained for bulk contaminations and surface
contaminations from several nuclides. An extrapolation to the CUORE background
has been performed.
-
We present a search for beta plus/EC double beta decay of 120Te performed
with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After
collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore
set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90%
C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the
two neutrino mode. These results improve the existing limits by almost three
orders of magnitude (four in the case of 0 neutrino mode).
-
We report the final result of the CUORICINO experiment. Operated between 2003
and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to
set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L.
The limit here reported includes the effects of systematic uncertainties that
are examined in detail in the paper. The corresponding upper bound on the
neutrino Majorana mass is in the range 300--710 meV, depending on the adopted
nuclear matrix element evaluation.
-
To better understand the contribution of cosmic ray muons to the CUORICINO
background, 10 plastic scintillator detectors were installed at the CUORICINO
site and operated during the final 3 months of the experiment. From these
measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained
on the cosmic ray-induced background in the neutrinoless double beta decay
region of interest. The measurements were also compared to Geant4 simulations.
-
A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta
($\nbb$) decay experiment is given and recent results are reported. CUORICINO
is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of
40.7 kg. It is cooled to $\sim 8-10$ mK by a dilution refrigerator shielded
from environmental radioactivity and energetic neutrons. It is running in the
Laboratori Nazionali del Gran Sasso (LNGS) in Assergi, Italy. These data
represent an exposure of $11.83\textrm{kg}...\textrm{y}$ or 91 mole-years of
$^{130}Te$. No evidence for $\nbb$-decay was observed and a limit of
$T^{0\nu}_{1/2}(^{130}Te)\geq3.0\times10^{24}$ y (90% C.L.) is set. This
corresponds to an upper limit on the effective mass, $< m_{\nu}>$, between 0.19
and 0.68 eV when analyzed with the many published nuclear structure
calculations. In the context of these nuclear models, the values fall within
the range corresponding to the claim of evidence of $\nbb$-decay by H.V.
Klapdor-Kleingrothaus, \textit{et al.} The experiment continues to acquire
data.
-
Neutrino oscillation experiments have proved that neutrinos are massive
particles, but can't determine their absolute mass scale. Therefore the
neutrino mass is still an open question in elementary particle physics. An
international collaboration is growing around the project of Microcalorimeter
Arrays for a Rhenium Experiment (MARE) for directly measuring the neutrino mass
with a sensitivity of about 0.2eV/c2. Many groups are joining their experiences
and technical expertise in a common effort towards this challenging experiment.
We discuss the different scenarios and the impact of MARE as a complement of
KATRIN.
-
We report the present results of CUORICINO a cryogenic experiment on
neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62
crystals of TeO2 with a total active mass of 40.7 kg. The array is framed
inside of a dilution refrigerator, heavily shielded against environmental
radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK
in the Gran Sasso Underground Laboratory. Temperature pulses induced by
particle interacting in the crystals are recorded and measured by means of
Neutron Transmutation Doped thermistors. The gain of each bolometer is
stabilized with voltage pulses developed by a high stability pulse generator
across heater resistors put in thermal contact with the absorber.
The calibration is performed by means of two thoriated wires routinely
inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of
130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the
lifetime of this process. Taking largely into account the uncertainties in the
theoretical values of nuclear matrix elements, this implies an upper boud on
the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This
sensitivity is similar to those of the 76Ge experiments.
-
We report on the final results of a series of experiments on double decay of
130Te carried out with an array of twenty cryogenic detectors. The set-up is
made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating
one for a cryogenic experiment. Four crystals are made with isotopically
enriched materials: two in 128Te and two others in 130Te. The remaining ones
are made with natural tellurium, which contains 31.7 % and 33.8 % 128Te and
130Te, respectively. The array was run under a heavy shield in the Gran Sasso
Underground Laboratory at a depth of about 3500 m.w.e. By recording the pulses
of each detector in anticoincidence with the others a lower limit of 2.1E23
years has been obtained at the 90 % C.L. on the lifetime for neutrinoless
double beta decay of 130Te. In terms of effective neutrino mass this is the
most restrictive limit in direct experiments, after those obtained with Ge
diodes. Limits on other lepton violating decays of 130Te and on the
neutrinoless double beta decay of 128Te to the ground state of 128Xe are also
reported and discussed. An indication is presented for the two neutrino double
beta decay of 130Te. Some consequences of the present results in the
interpretation of geochemical experiments are discussed.
-
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being
a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical
towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers
of 4 crystals. The design of the detector is optimized for ultralow-background
searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold
dark matter, solar axions, and rare nuclear decays. A preliminary experiment
involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE
tower is being constructed as a smaller scale experiment called CUORICINO. The
expected performance and sensitivity, based on Monte Carlo simulations and
extrapolations of present results, are reported.
-
Electron capture of 123Te from the K shell has been investigated in a new
underground search with an array of 340 g TeO_2 thermal detectors. We find that
some previous indication of this decay could be attributed to E.C. of 121Te
resulting from neutron activation of natural Tellurium. There is therefore so
far no evidence for E.C. of 123Te from the K shell with a 90 % c.l. lower limit
t_{1/2}^K > 5.E19 years on the half lifetime. Taking into account the predicted
K E.C. branching ratio, the corresponding lower limit on the 123Te EC half
lifetime is t_{1/2} > 9.2E16 y, which can be theoretically interpreted only on
the basis of a strong suppression of the nuclear matrix elements. A
complementary analysis based on the expected fraction of E.C. accompanied by
internal bremsstrahlung is discussed.