This paper reports the first simultaneous measurement of the horizontal and
vertical components of the polarization vector in a storage ring under the
influence of a radio frequency (rf) solenoid. The experiments were performed at
the Cooler Synchrotron COSY in J\"ulich using a vector polarized, bunched
$0.97\,\textrm{GeV/c}$ deuteron beam. Using the new spin feedback system, we
set the initial phase difference between the solenoid field and the precession
of the polarization vector to a predefined value. The feedback system was then
switched off, allowing the phase difference to change over time, and the
solenoid was switched on to rotate the polarization vector. We observed an
oscillation of the vertical polarization component and the phase difference.
The oscillations can be described using an analytical model. The results of
this experiment also apply to other rf devices with horizontal magnetic fields,
such as Wien filters. The precise manipulation of particle spins in storage
rings is a prerequisite for measuring the electric dipole moment (EDM) of
charged particles.
-
In this paper, we demonstrate the connection between a magnetic storage ring
with additional sextupole fields set so that the x and y chromaticities vanish
and the maximizing of the lifetime of in-plane polarization (IPP) for a
0.97-GeV/c deuteron beam. The IPP magnitude was measured by continuously
monitoring the down-up scattering asymmetry (sensitive to sideways
polarization) in an in-beam, carbon-target polarimeter and unfolding the
precession of the IPP due to the magnetic anomaly of the deuteron. The optimum
operating conditions for a long IPP lifetime were made by scanning the field of
the storage ring sextupole magnet families while observing the rate of IPP loss
during storage of the beam. The beam was bunched and electron cooled. The IPP
losses appear to arise from the change of the orbit circumference, and
consequently the particle speed and spin tune, due to the transverse betatron
oscillations of individual particles in the beam. The effects of these changes
are canceled by an appropriate sextupole field setting.
-
This letter reports the successful use of feedback from a spin polarization
measurement to the revolution frequency of a 0.97 GeV/$c$ bunched and polarized
deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control
both the precession rate ($\approx 121$ kHz) and the phase of the horizontal
polarization component. Real time synchronization with a radio frequency (rf)
solenoid made possible the rotation of the polarization out of the horizontal
plane, yielding a demonstration of the feedback method to manipulate the
polarization. In particular, the rotation rate shows a sinusoidal function of
the horizontal polarization phase (relative to the rf solenoid), which was
controlled to within a one standard deviation range of $\sigma = 0.21$ rad. The
minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753
kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a
requirement for the use of storage rings to look for an intrinsic electric
dipole moment of charged particles.
-
A new method to determine the spin tune is described and tested. In an ideal
planar magnetic ring, the spin tune - defined as the number of spin precessions
per turn - is given by $\nu_s = \gamma G$ (gamma is the Lorentz factor, $G$ the
magnetic anomaly). For 970 MeV/c deuterons coherently precessing with a
frequency of ~120 kHz in the Cooler Synchrotron COSY, the spin tune is deduced
from the up-down asymmetry of deuteron carbon scattering. In a time interval of
2.6 s, the spin tune was determined with a precision of the order $10^{-8}$,
and to $1 \cdot 10^{-10}$ for a continuous 100 s accelerator cycle. This
renders the presented method a new precision tool for accelerator physics:
controlling the spin motion of particles to high precision is mandatory, in
particular, for the measurement of electric dipole moments of charged particles
in a storage ring.
-
Precision experiments, such as the search for electric dipole moments of
charged particles using storage rings, demand for an understanding of the spin
dynamics with unprecedented accuracy. The ultimate aim is to measure the
electric dipole moments with a sensitivity up to 15 orders in magnitude better
than the magnetic dipole moment of the stored particles. This formidable task
requires an understanding of the background to the signal of the electric
dipole from rotations of the spins in the spurious magnetic fields of a storage
ring. One of the observables, especially sensitive to the imperfection magnetic
fields in the ring is the angular orientation of stable spin axis. Up to now,
the stable spin axis has never been determined experimentally, and in addition,
the JEDI collaboration for the first time succeeded to quantify the background
signals that stem from false rotations of the magnetic dipole moments in the
horizontal and longitudinal imperfection magnetic fields of the storage ring.
To this end, we developed a new method based on the spin tune response of a
machine to artificially applied longitudinal magnetic fields. This novel
technique, called \textit{spin tune mapping}, emerges as a very powerful tool
to probe the spin dynamics in storage rings. The technique was experimentally
tested in 2014 at the cooler synchrotron COSY, and for the first time, the
angular orientation of the stable spin axis at two different locations in the
ring has been determined to an unprecedented accuracy of better than
$2.8\mu$rad.
-
Modern precision neutrino experiments like Double Chooz require a highly
efficient trigger system in order to reduce systematic uncertainties. The
trigger and timing system of the Double Chooz experiment was designed according
to this goal. The Double Chooz trigger system is driven by the basic idea of
triggering on multiple thresholds according to the total visible energy and
additionally triggering on the number of active photomultiplier tubes (PMTs) in
the detector. To do so, the trigger system continuously monitors the analogue
signals from all PMTs in the detector. The amplitudes of these PMT-signals are
summed for groups of certain PMTs (group signals) and for all PMTs (sum
signal), respectively. The group signals are discriminated by two thresholds
for each input channel and four thresholds for the sum signal. The resulting
signals are processed by the trigger logic unit which is implemented in a FPGA.
In addition to the proper trigger, the trigger system provides a common clock
signal for all subsequent data acquisition systems to guarantee a synchronous
readout of the Double Chooz detectors. The present design of the system
provides a high flexibility for the applied logic and settings, making it
useful for experiments other than Double Chooz. The Double Chooz trigger and
timing system was installed and commissioned in 2011. This article describes
the hardware of the trigger and timing system. Furthermore the setup,
implemented trigger logic and performance of the trigger and timing system for
the Double Chooz experiment is presented.