This archive summarizes a working paper and conference proceedings related to
laser wire scanner development for the Future Linear Collider (FLC) in the
years 2001 to 2006. In particular the design, setup and data taking for the
laser wire experiments at PETRA II and CT2 are described. The material is
focused on the activities undertaken by Royal Holloway University of London
(RHUL).
-
The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for
final focus beam lines of linear high energy colliders. This paper describes
the high resolution cavity beam position monitor (BPM) system, which is a part
of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at
6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The
cavities, electronics, and digital processing are described. The resolution of
the C-band system with attenuators was determined to be approximately 250 nm
and 1 m for the S-band system. Without attenuation the best recorded C-band
cavity resolution was 27 nm.
-
The SLAC Linac can deliver damped bunches with ILC parameters for bunch
charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be
delivered there, parasitic with PEP-II operation. We plan to use this facility
to test prototype components of the Beam Delivery System and Interaction
Region. We discuss our plans for this ILC Test Facility and preparations for
carrying out experiments related to collimator wakefields and energy
spectrometers. We also plan an interaction region mockup to investigate effects
from backgrounds and beam-induced electromagnetic interference.
-
As a joint effort in the JLC/NLC research program, we have developed a new
type of damped detuned accelerator structure with optimized round-shaped
cavities (RDDS). This paper discusses some important R&D aspects of the first
structure in this series (RDDS1). The design aspects covered are the cell
design with sub-MHz precision, HOM detuning, coupling and damping technique and
wakefield simulation. The fabrication issues covered are ultra-precision cell
machining with micron accuracy, assembly and diffusion bonding technologies to
satisfactorily meet bookshelf, straightness and cell rotational alignment
requirements. The measurements described are the RF properties of single
cavities and complete accelerator section, as well as wakefields from the ASSET
tests at SLAC. Finally, future improvements are also discussed.