In this paper, we describe the XENON100 data analyses used to assess the
target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and
krypton ($^{85}$Kr). We detail the event selections of high-energy alpha
particles and decay-specific delayed coincidences. We derive distributions of
the individual radionuclides inside the detector and quantify their abundances
during the main three science runs of the experiment over a period of $\sim$ 4
years, from January 2010 to January 2014. We compare our results to external
measurements of radon emanation and krypton concentrations where we find good
agreement. We report an observed reduction in concentrations of radon daughters
that we attribute to the plating-out of charged ions on the negatively biased
cathode.
-
We report on the response of liquid xenon to low energy electronic recoils
below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm
and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method
based on Markov Chain Monte Carlo is used to extract the photon yields and
recombination fluctuations from the experimental data. The photon yields
measured at the two lower fields are in agreement with those from literature;
additional measurements at a higher field of 366 V/cm are presented. The
electronic and nuclear recoil discrimination as well as its dependence on the
drift field and photon detection efficiency are investigated at these low
energies. The results provide new measurements in the energy region of interest
for dark matter searches using liquid xenon.
-
We report the first dark matter search results from XENON1T, a
$\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber
in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first
ton-scale detector of this kind. The blinded search used 34.2 live days of data
acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg
fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of
interest for WIMP dark matter searches, the electronic recoil background was
$(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times
\mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter
detector. A profile likelihood analysis shows that the data is consistent with
the background-only hypothesis. We derive the most stringent exclusion limits
on the spin-independent WIMP-nucleon interaction cross section for WIMP masses
above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for
35-GeV/c${}^2$ WIMPs at 90% confidence level.
-
We present results of searches for vector and pseudo-scalar bosonic
super-WIMPs, which are dark matter candidates with masses at the keV-scale,
with the XENON100 experiment. XENON100 is a dual-phase xenon time projection
chamber operated at the Laboratori Nazionali del Gran Sasso. A profile
likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg
showed no evidence for a signal above the expected background. We thus obtain
new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range,
excluding couplings to electrons with coupling constants of $g_{ae} >
3\times10^{-13}$ for pseudo-scalar and $\alpha'/\alpha > 2\times10^{-28}$ for
vector super-WIMPs, respectively. These limits are derived under the assumption
that super-WIMPs constitute all of the dark matter in our galaxy.
-
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
-
We describe the purification of xenon from traces of the radioactive noble
gas radon using a cryogenic distillation column. The distillation column is
integrated into the gas purification loop of the XENON100 detector for online
radon removal. This enabled us to significantly reduce the constant $^{222}$Rn
background originating from radon emanation. After inserting an auxiliary
$^{222}$Rn emanation source in the gas loop, we determined a radon reduction
factor of R > 27 (95% C.L.) for the distillation column by monitoring the
$^{222}$Rn activity concentration inside the XENON100 detector.
-
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the $\beta$-emitter
$^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon $\rm{^{nat}}$Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10$^{-15}$ mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.4$\cdot$10$^5$ with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of $\rm{^{nat}}$Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN.
-
We report on WIMP search results in the XENON100 detector using a
non-relativistic effective field theory approach. The data from science run II
(34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil
energy interval compared to previous analyses, ranging from $(6.6 -
240)~\mathrm{keV_\mathrm{nr}}$. The data is found to be compatible with the
background-only hypothesis. We present 90% confidence level exclusion limits on
the coupling constants of WIMP-nucleon effective operators using a binned
profile likelihood method. We also consider the case of inelastic WIMP
scattering, where incident WIMPs may up-scatter to a higher mass state, and set
exclusion limits on this model as well.
-
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive
Particles (WIMPs) through low-energy interactions with xenon atoms. To detect
such a rare event necessitates the use of radiopure materials to minimize the
number of background events within the expected WIMP signal region. In this
paper we report the results of an extensive material radioassay campaign for
the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry
techniques, systematic measurements of trace radioactive impurities in over one
hundred samples within a wide range of materials were performed. The measured
activities allowed for stringent selection and placement of materials during
the detector construction phase and provided the input for XENON1T detection
sensitivity estimates through Monte Carlo simulations.
-
We present the first constraints on the spin-dependent, inelastic scattering
cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from
XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a
dual-phase xenon time projection chamber with 62\,kg of active mass, operated
at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to
search for nuclear recoils from WIMP-nucleus interactions. Here we explore
inelastic scattering, where a transition to a low-lying excited nuclear state
of $^{129}$Xe is induced. The experimental signature is a nuclear recoil
observed together with the prompt de-excitation photon. We see no evidence for
such inelastic WIMP-$^{129}$Xe interactions. A profile likelihood analysis
allows us to set a 90\% C.L. upper limit on the inelastic, spin-dependent
WIMP-nucleon cross section of $3.3 \times 10^{-38}$\,cm$^{2}$ at
100\,GeV/c$^2$. This is the most constraining result to date, and sets the
pathway for an analysis of this interaction channel in upcoming, larger
dual-phase xenon detectors.
-
A Rn-220 source is deployed on the XENON100 dark matter detector in order to
address the challenges in calibration of tonne-scale liquid noble element
detectors. We show that the Pb-212 beta emission can be used for low-energy
electronic recoil calibration in searches for dark matter. The isotope spreads
throughout the entire active region of the detector, and its activity naturally
decays below background level within a week after the source is closed. We find
no increase in the activity of the troublesome Rn-222 background after
calibration. Alpha emitters are also distributed throughout the detector and
facilitate calibration of its response to Rn-222. Using the delayed coincidence
of Rn-220/Po-216, we map for the first time the convective motion of particles
in the XENON100 detector. Additionally, we make a competitive measurement of
the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.
-
We present the first search for dark matter-induced delayed coincidence
signals in a dual-phase xenon time projection chamber, using the 224.6\,live
days of the XENON100 science run~II. This very distinct signature is predicted
in the framework of magnetic inelastic dark matter which has been proposed to
reconcile the modulation signal reported by the DAMA/LIBRA collaboration with
the null results from other direct detection experiments. No candidate event
has been found in the region of interest and upper limits on the WIMP's
magnetic dipole moment are derived. The scenarios proposed to explain the
DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of
WIMPs with masses of 58.0\,GeV/c$^2$ and 122.7\,GeV/c$^2$ are excluded at
3.3\,$\sigma$ and 9.3\,$\sigma$, respectively.
-
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For $^{124}$Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of $^{124}$Xe using
7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
$T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
-
We report on WIMP search results of the XENON100 experiment, combining three
runs summing up to 477 live days from January 2010 to January 2014. Data from
the first two runs were already published. A blind analysis was applied to the
last run recorded between April 2013 and January 2014 prior to combining the
results. The ultra-low electromagnetic background of the experiment, ~$5 \times
10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic
recoil rejection, together with the increased exposure of 48 kg $\times$ yr
improves the sensitivity. A profile likelihood analysis using an energy range
of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic,
spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8
GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and
90% confidence level. We also report updated constraints on the elastic,
spin-dependent WIMP-nucleon cross sections obtained with the same data. We set
upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0
$\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50
GeV/$c^2$, at 90% confidence level.
-
We report on a search for electronic recoil event rate modulation signatures
in the XENON100 data accumulated over a period of 4 years, from January 2010 to
January 2014. A profile likelihood method, which incorporates the stability of
the XENON100 detector and the known electronic recoil background model, is used
to quantify the significance of periodicity in the time distribution of events.
There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in
the low energy region of $(2.0-5.8)$ keV in the single scatter event sample,
with a global significance of $1.9\,\sigma$, however no other more significant
modulation is observed. The expected annual modulation of a dark matter signal
is not compatible with this result. Single scatter events in the low energy
region are thus used to exclude the DAMA/LIBRA annual modulation as being due
to dark matter electron interactions via axial vector coupling at
$5.7\,\sigma$.
-
We report on a dark matter search for a Weakly Interacting Massive Particle
(WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the
EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data
from eight selected detectors with the lowest energy thresholds leading to a
combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$-
and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector
intrinsic backgrounds were modelled from data outside the region of interest
and constrained in the analysis. The basic data selection and most of the
background models are the same as those used in a previously published analysis
based on Boosted Decision Trees (BDT). For the likelihood approach applied in
the analysis presented here, a larger signal efficiency and a subtraction of
the expected background lead to a higher sensitivity, especially for the lowest
WIMP masses probed. No statistically significant signal was found and upper
limits on the spin-independent WIMP-nucleon scattering cross section can be set
with a hypothesis test based on the profile likelihood test statistics. The 90%
C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6
\times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven
with respect to the BDT-based analysis. For WIMP masses above
$15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in
good agreement.
-
We present a measurement of the cosmogenic activation in the germanium
cryogenic detectors of the EDELWEISS III direct dark matter search experiment.
The decay rates measured in detectors with different exposures to cosmic rays
above ground are converted into production rates of different isotopes. The
measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H,
2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for
$^{65}$Zn. These results are the most accurate for these isotopes. A lower
limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also
presented. They are compared to model predictions present in literature and to
estimates calculated with the ACTIVIA code.
-
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge
detectors Fully covered with Inter-Digitized electrodes (FID). They are
operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence
charge-carrier trapping significantly affects both the ionization and heat
energy measurements. This paper describes an analytical model of the signals
induced by trapped charges in FID detectors based on the Shockley-Ramo theorem.
It is used to demonstrate that veto electrodes, initially designed for the sole
purpose of surface event rejection, can be used to provide a sensitivity to the
depth of the energy deposits, characterize the trapping in the crystals,
perform heat and ionization energy corrections and improve the ionization
baseline resolutions. These procedures are applied successfully to actual data.
-
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
-
Recent results from the PICASSO dark matter search experiment at SNOLAB are
reported. These results were obtained using a subset of 10 detectors with a
total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low
backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be
obtained which results in an increased sensitivity to interactions from Weakly
Interacting Massive Particles (WIMPs) with masses below 10 GeV/c^2. No dark
matter signal was found. Best exclusion limits in the spin dependent sector
were obtained for WIMP masses of 20 GeV/c^2 with a cross section on protons of
sigma_p^SD = 0.032 pb (90% C.L.). In the spin independent sector close to the
low mass region of 7 GeV/c2 favoured by CoGeNT and DAMA/LIBRA, cross sections
larger than sigma_p^SI = 1.41x10^-4 pb (90% C.L.) are excluded.
-
We report new results obtained in calibrations of superheated liquid droplet
detectors used in dark matter searches with different radiation sources
(n,$\alpha$,$\gamma$). In particular, detectors were spiked with alpha-emitters
located inside and outside the droplets. It is shown that the responses are
different, depending on whether alpha particles or recoil nuclei create the
signals. The energy thresholds for $\alpha$-emitters are compared with test
beam measurements using mono-energetic neutrons, as well as with theoretical
predictions. Finally a model is presented which describes how the observed
intensities of particle induced acoustic signals can be related to the dynamics
of bubble growth in superheated liquids. An improved understanding of the
bubble dynamics is an important first step in obtaining better discrimination
between particle types interacting in detectors of this kind.
-
The PICASSO experiment at SNOLAB reports new results for spin-dependent WIMP
interactions on $^{19}$F using the superheated droplet technique. A new
generation of detectors and new features which enable background discrimination
via the rejection of non-particle induced events are described. First results
are presented for a subset of two detectors with target masses of $^{19}$F of
65 g and 69 g respectively and a total exposure of 13.75 $\pm$ 0.48 kgd. No
dark matter signal was found and for WIMP masses around 24 GeV/c$^2$ new limits
have been obtained on the spin-dependent cross section on $^{19}$F of
$\sigma_F$ = 13.9 pb (90% C.L.) which can be converted into cross section
limits on protons and neutrons of $\sigma_p$ = 0.16 pb and $\sigma_n$ = 2.60 pb
respectively (90% C.L). The obtained limits on protons restrict recent
interpretations of the DAMA/LIBRA annual modulations in terms of spin-dependent
interactions.
-
The PICASSO collaboration observed for the first time a significant
difference between the acoustic signals induced by neutrons and alpha particles
in a detector based on superheated liquids. This new discovery offers the
possibility of improved background suppression and could be especially useful
for dark matter experiments. This new effect may be attributed to the formation
of multiple bubbles on alpha tracks, compared to single nucleations created by
neutron induced recoils.