PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
-
The high quantum efficiencies (QE) of backside illuminated charge coupled
devices (CCD) has ushered in the age of the large scale astronomical survey.
The QE of these devices can be greater than 90 %, and is dependent upon the
operating temperature, device thickness, backside charging mechanisms, and
anti-reflection (AR) coatings. But at optical wavelengths the QE is well
approximated as one minus the reflectance, thus the measurement of the backside
reflectivity of these devices provides a second independent measure of their
QE.
We have designed and constructed a novel instrument to measure the relative
specular reflectance of CCD detectors, with a significant portion of this
device being constructed using a 3D fused deposition model (FDM) printer. This
device implements both a monitor and measurement photodiode to simultaneously
collect incident and reflected measurements reducing errors introduced by the
relative reflectance calibration process. While most relative reflectometers
are highly dependent upon a precisely repeatable target distance for accurate
measurements, we have implemented a method of measurement which minimizes these
errors.
Using the reflectometer we have measured the reflectance of two types of
Hamamatsu CCD detectors. The first device is a Hamamatsu 2k x 4k backside
illuminated high resistivity p-type silicon detector which has been optimized
to operate in the blue from 380 nm - 650 nm. The second detector being a 2k x
4k backside illuminated high resistivity p-type silicon detector optimized for
use in the red from 640 nm - 960 nm. We have not only been able to measure the
reflectance of these devices as a function of wavelength we have also sampled
the reflectance as a function of position on the device, and found a reflection
gradient across these devices.
-
We describe the design and performance of the SuMIRe Prime Focus Spectrograph
(PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed
ground-based spectrograph consisting of four identical spectrograph modules,
each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the
prime focus. Each spectrograph module has three channels covering wavelength
ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the
dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera.
The cameras are very large, having a clear aperture of 300~mm at the entrance
window, and a mass of $\sim$280~kg. In this paper we describe the design of the
visible camera cryostats and discuss various aspects of cryostat performance.
-
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
-
We describe the infrastructure being developed to align and characterize the
detectors for the Subaru Measurement of Images and Redshifts (SuMIRe) Prime
Focus Spectrograph (PFS). PFS will employ four three-channel spectrographs with
an operating wavelength range of 3800 $\AA$ to 12600 $\AA$. Each spectrograph
will be comprised of two visible channels and one near infrared (NIR) channel,
where each channel will use a separate Schmidt camera to image the captured
spectra onto their respective detectors. In the visible channels, Hamamatsu 2k
x 4k CCDs will be mounted in pairs to create a single 4k x 4k detector, while
the NIR channel will use a single Teledyne 4k x 4k H4RG HgCdTe device.
-
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.
-
We present the detailed design of the near infrared camera for the SuMIRe
(Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS)
being developed for the Subaru Telescope. The PFS spectrograph is designed to
collect spectra from 2394 objects simultaneously, covering wavelengths that
extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical
spectrograph modules, with each module collecting roughly 600 spectra from a
robotic fiber positioner at the telescope prime focus. Each spectrograph module
will have two visible channels covering wavelength ranges 380 nm - 640 nm and
640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range
955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal
length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector
format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff
device is used. In the visible channels, CCDs from Hamamatsu are used. These
cameras are large, having a clear aperture of 300 mm at the entrance window,
and a mass of ~ 250 kg.
Like the two visible channel cameras, the NIR camera contains just four
optical elements: a two-element refractive corrector, a Mangin mirror, and a
field flattening lens. This simple design produces very good imaging
performance considering the wide field and wavelength range, and it does so in
large part due to the use of a Mangin mirror (a lens with a reflecting rear
surface) for the Schmidt primary. In the case of the NIR camera, the rear
reflecting surface is a dichroic, which reflects in-band wavelengths and
transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection
filter coating on the rear surface of the second corrector element, greatly
reduces the out-of-band thermal radiation that reaches the detector.