• We present total and specular reflectance measurements of various materials that are commonly (and uncommonly) used to provide baffling and/or to minimize the effect of stray light in optical systems. More specifically, we investigate the advantage of using certain black surfaces and their role in suppressing stray light on detectors in optical systems. We measure the total reflectance of the samples over a broad wavelength range (250 < lambda < 2500 nm) that is of interest to astronomical instruments in the ultraviolet, visible, and near-infrared regimes. Additionally, we use a helium-neon laser to measure the specular reflectance of the samples at various angles. Finally, we compare these two measurements and derive the specular fraction for each sample.
  • We present optical (BVRI) photometric measurements of a sample of 76 common proper motion wide separation main sequence binary pairs. The pairs are composed of a F-, G-, or K-type primary star and an M-type secondary. The sample is selected from the revised NLTT catalog and the LSPM catalog. The photometry is generally precise to 0.03 mag in all bands. We separate our sample into two groups, dwarf candidates and subdwarf candidates, using the reduced proper motion (RPM) diagram constructed with our improved photometry. The M subdwarf candidates in general have larger $V-R$ colors than the M dwarf candidates at a given $V-I$ color. This is consistent with an average metallicity difference between the two groups, as predicted by the PHOENIX/BT-Settl models. The improved photometry will be used as input into a technique to determine the metallicities of the M-type stars.
  • DECal is a new calibration system for the CTIO 4 m Blanco telescope. It is currently being installed as part of the Dark Energy Survey and will provide both broadband flat fields and narrowband (about 1 nm bandwidth) spectrophotometric calibration for the new Dark Energy Camera (DECam). Both of these systems share a new Lambertian flat field screen. The broadband flat field system uses LEDs to illuminate each photometric filter. The spectrophotometric calibration system consists of a monochromator-based tunable light source that is projected onto the flat field screen using a custom line-to-spot fiber bundle and an engineered diffuser. Several calibrated photodiodes positioned along the beam monitor the telescope throughput as a function of wavelength. This system will measure the wavelength-dependent instrumental response function of the total telescope+instrument system in the range 300 < lambda < 1100nm. The spectrophotometric calibration will be performed regularly (roughly once per month) to determine the spectral response of the DECam system and to monitor changes in instrumental throughput during the five year Dark Energy Survey project.