The $(x, y)$ position reconstruction method used in the analysis of the
complete exposure of the Large Underground Xenon (LUX) experiment is presented.
The algorithm is based on a statistical test that makes use of an iterative
method to recover the photomultiplier tube (PMT) light response directly from
the calibration data. The light response functions make use of a two
dimensional functional form to account for the photons reflected on the inner
walls of the detector. To increase the resolution for small pulses, a photon
counting technique was employed to describe the response of the PMTs. The
reconstruction was assessed with calibration data including
${}^{\mathrm{83m}}$Kr (releasing a total energy of 41.5 keV) and ${}^{3}$H
($\beta^-$ with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron
beam (2.45 MeV). In the horizontal plane, the reconstruction has achieved an
$(x, y)$ position uncertainty of $\sigma$= 0.82 cm for events of only 200
electroluminescence photons and $\sigma$ = 0.17 cm for 4,000
electroluminescence photons. Such signals are associated with electron recoils
of energies $\sim$0.25 keV and $\sim$10 keV, respectively. The reconstructed
position of the smallest events with a single electron emitted from the liquid
surface has a horizontal $(x, y)$ uncertainty of 2.13 cm.
-
This work details the development of a three-dimensional (3D) electric field
model for the LUX detector. The detector took data during two periods of
searching for weakly interacting massive particle (WIMP) searches. After the
first period completed, a time-varying non-uniform negative charge developed in
the polytetrafluoroethylene (PTFE) panels that define the radial boundary of
the detector's active volume. This caused electric field variations in the
detector in time, depth and azimuth, generating an electrostatic
radially-inward force on electrons on their way upward to the liquid surface.
To map this behavior, 3D electric field maps of the detector's active volume
were built on a monthly basis. This was done by fitting a model built in COMSOL
Multiphysics to the uniformly distributed calibration data that were collected
on a regular basis. The modeled average PTFE charge density increased over the
course of the exposure from -3.6 to $-5.5~\mu$C/m$^2$. From our studies, we
deduce that the electric field magnitude varied while the mean value of the
field of $\sim200$~V/cm remained constant throughout the exposure. The varying
electric fields and their impact on event reconstruction and discrimination
were successfully modeled.
-
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$
and fluctuations for electronic recoil events in liquid xenon at discrete
energies between 186 eV and 33.2 keV. The average electric field applied across
the liquid xenon target is 180 V/cm. The data are obtained using low energy
$^{127}$Xe electron capture decay events from the 95.0-day first run from LUX
(WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The
sequence of gamma-ray and X-ray cascades associated with $^{127}$I
de-excitations produces clearly identified 2-vertex events in the LUX detector.
We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and
N- (186 eV) shell cascade events and verify that the relative ratio of observed
events for each shell agrees with calculations. The N-shell cascade analysis
includes single extracted electron (SE) events and represents the lowest-energy
electronic recoil $\textit{in situ}$ measurements that have been explored in
liquid xenon.
-
LUX was the first dark matter experiment to use a $^{83\textrm{m}}$Kr
calibration source. In this paper we describe the source preparation and
injection. We also present several $^{83\textrm{m}}$Kr calibration applications
in the context of the 2013 LUX exposure, including the measurement of temporal
and spatial variation in scintillation and charge signal amplitudes, and
several methods to understand the electric field within the time projection
chamber.
-
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
-
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
-
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
-
We propose a new technique for the calibration of nuclear recoils in large
noble element dual-phase time projection chambers used to search for WIMP dark
matter in the local galactic halo. This technique provides an $\textit{in
situ}$ measurement of the low-energy nuclear recoil response of the target
media using the measured scattering angle between multiple neutron interactions
within the detector volume. The low-energy reach and reduced systematics of
this calibration have particular significance for the low-mass WIMP sensitivity
of several leading dark matter experiments. Multiple strategies for improving
this calibration technique are discussed, including the creation of a new type
of quasi-monoenergetic 272 keV neutron source. We report results from a
time-of-flight based measurement of the neutron energy spectrum produced by an
Adelphi Technology, Inc. DD108 neutron generator, confirming its suitability
for the proposed nuclear recoil calibration.
-
We present the first experimental constraints on the spin-dependent
WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a
dual-phase xenon time projection chamber operating at the Sanford Underground
Research Facility (Lead, South Dakota), which is designed to observe the recoil
signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood
ratio analysis of $1.4~\times~10^{4}~\text{kg}\cdot~\text{days}$ of fiducial
exposure allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n~=~9.4~\times~10^{-41}~\text{cm}^2$
($\sigma_p~=~2.9~\times~10^{-39}~\text{cm}^2$) at 33 GeV/c$^2$. The
spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
-
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
-
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
-
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
-
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
-
Dark matter direct-detection searches for weakly interacting massive
particles (WIMPs) are commonly limited in sensitivity by neutron and gamma
backgrounds from the decay of radioactive isotopes. Several common
radioisotopes in detector construction materials are found in long decay
chains, notably those headed by 238U, 235U, and 232Th. Gamma radioassay using
Ge detectors identifies decay rates of a few of the radioisotopes in each
chain, and typically assumes that the chain is in secular equilibrium. If the
chains are out of equilibrium, detector background rates can be elevated
significantly above expectation. In this work we quantify the increase in
neutron and gamma production rates from an excess of various sub-chains of the
238U decay chain. We find that the 226Ra sub-chain generates x10 higher neutron
flux per decay than the 238U early sub-chain and 210Pb sub-chain, in materials
with high (alpha,n) neutron yields. Typical gamma screening results limit
potential 238U early sub-chain activity to x20-60 higher than 226Ra sub-chain
activity. Monte Carlo simulation is used to quantify the contribution of the
sub-chains of 238U to low-energy nuclear recoil (NR) and electron recoil (ER)
backgrounds in simplified one tonne liquid Ar and liquid Xe detectors. NR and
ER rates generated by 238U sub-chains in the Ar and Xe detectors are found
after comparable fiducial and multiple-scatter cuts. The Xe detector is found
to have x12 higher signal-to-background for 100 GeV WIMPs over neutrons than
the Ar detector. ER backgrounds in both detectors are found to increase weakly
for excesses of 238U early sub-chain and 210Pb sub-chain relative to 226Ra
sub-chain. Experiments in which backgrounds are NR-dominated are sensitive to
undetected excesses of 238U early sub-chain and 210Pb sub-chain concentrations.
Experiments with ER-dominated backgrounds are relatively insensitive to these
excesses.
-
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
-
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
-
The Large Underground Xenon (LUX) collaboration has designed and constructed
a dual-phase xenon detector, in order to conduct a search for Weakly
Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal
of the LUX detector is to clearly detect (or exclude) WIMPS with a spin
independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$,
equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume
(FV) of the 370-kg detector. The overall background goals are set to have $<$1
background events characterized as possible WIMPs in the FV in 300 days of
running.
This paper describes the design and construction of the LUX detector.
-
We report on the screening of samples of titanium metal for their
radio-purity. The screening process described in this work led to the selection
of materials used in the construction of the cryostats for the Large
Underground Xenon (LUX) dark matter experiment. Our measurements establish
titanium as a highly desirable material for low background experiments
searching for rare events. The sample with the lowest total long-lived activity
was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2
mBq/kg of K-40. Measurements of several samples also indicated the presence of
short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon
initiated (n,p) reactions.
-
Geant4 has been used throughout the nuclear and high-energy physics community
to simulate energy depositions in various detectors and materials. These
simulations have mostly been run with a source beam outside the detector. In
the case of low-background physics, however, a primary concern is the effect on
the detector from radioactivity inherent in the detector parts themselves. From
this standpoint, there is no single source or beam, but rather a collection of
sources with potentially complicated spatial extent. LUXSim is a simulation
framework used by the LUX collaboration that takes a component-centric approach
to event generation and recording. A new set of classes allows for multiple
radioactive sources to be set within any number of components at run time, with
the entire collection of sources handled within a single simulation run.
Various levels of information can also be recorded from the individual
components, with these record levels also being set at runtime. This
flexibility in both source generation and information recording is possible
without the need to recompile, reducing the complexity of code management and
the proliferation of versions. Within the code itself, casting geometry objects
within this new set of classes rather than as the default Geant4 classes
automatically extends this flexibility to every individual component. No
additional work is required on the part of the developer, reducing development
time and increasing confidence in the results. We describe the guiding
principles behind LUXSim, detail some of its unique classes and methods, and
give examples of usage.
* Corresponding author, kareem@llnl.gov
-
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
-
A study of the current status of WIMP dark matter searches has been made in
the context of scientific and technical planning for a Deep Underground Science
and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter Candidates and New Physics in the Laboratory
6. Synergies with Other Sub-Fields
7. Direct Detection Experiments: Status and Future Prospects
8. Infrastructure
9. International Context
10. Summary and Outlook
11. Acknowledgments
-
Experimentally have we got what it takes to pursue the direct observation of
WIMP interactions down to sensitivities of a few events /100 kg/year? For a Ge
target with a low energy threshold (<20 keVr) this corresponds to a
WIMP-nucleon sigma~10^-46 cm^2. A number of recent theoretical papers, making
calculations in SUSY-based frameworks, show many (>5) orders of magnitude
spread in the possible interaction rates for models consistent with existing
Cosmology and Accelerator bounds. Some theorists, but certainly not all, are
able to generate models, that lead to interaction rates at the few /kg/day that
would be implied by the current DAMA annual modulation signal. All theorists
demonstrate models that generate much lower interaction rates. This paper takes
an unashamed experimentalist`s view of the issues that arise when looking
forward to constructing 1 tonne WIMP detectors.
-
A new method is proposed for extracting limits on spin-dependent WIMP-nucleon
interaction cross sections from direct detection dark matter experiments. The
new method has the advantage that the limits on individual WIMP-proton and
WIMP-neutron cross sections for a given WIMP mass can be combined in a simple
way to give a model-independent limit on the properties of WIMPs scattering
from both protons and neutrons in the target nucleus. Extension of the
technique to the case of a target material consisting of several different
species of nuclei is discussed.