In this paper, we describe the first tests of a dual-readout fiber
calorimeter in which silicon photomultipliers are used to sense the
(scintillation and Cherenkov) light signals. The main challenge in this
detector is implementing a design that minimizes the optical crosstalk between
the two types of fibers, which are located very close to each other and carry
light signals that differ in intensity by about a factor of 60. The
experimental data, which were obtained with beams of high-energy electrons and
muons as well as in lab tests, illustrate to what extent this challenge was
met. The Cherenkov light yield, a limiting factor for the energy resolution of
this type of calorimeter, was measured to be about twice that of the previously
tested configurations based on photomultiplier tubes. The lateral profiles of
electromagnetic showers were measured on a scale of millimeters from the shower
axis and significant differences were found between the profiles measured with
the scintillating and the Cherenkov fibers.