A large prototype of 1.3m3 was designed and built as a demonstrator of the
semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC
experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each
unit is built of an active layer made of 1m2 Glass Resistive Plate
Chamber(GRPC) detector placed inside a cassette whose walls are made of
stainless steel. The cassette contains also the electronics used to read out
the GRPC detector. The lateral granularity of the active layer is provided by
the electronics pick-up pads of 1cm2 each. The cassettes are inserted into a
self-supporting mechanical structure built also of stainless steel plates
which, with the cassettes walls, play the role of the absorber. The prototype
was designed to be very compact and important efforts were made to minimize the
number of services cables to optimize the efficiency of the Particle Flow
Algorithm techniques to be used in the future ILC experiments. The different
components of the SDHCAL prototype were studied individually and strict
criteria were applied for the final selection of these components. Basic
calibration procedures were performed after the prototype assembling. The
prototype is the first of a series of new-generation detectors equipped with a
power-pulsing mode intended to reduce the power consumption of this highly
granular detector. A dedicated acquisition system was developed to deal with
the output of more than 440000 electronics channels in both trigger and
triggerless modes. After its completion in 2011, the prototype was commissioned
using cosmic rays and particles beams at CERN.
-
The recent progress in R&D of the Micromegas detectors for hadronic
calorimetry including new engineering-technical solutions, electronics
development, and accompanying simulation studies with emphasis on the
comparison of the physics performance of the analog and digital readout is
described. The developed prototypes are with 2 bit digital readout to exploit
the Micromegas proportional mode and thus improve the calorimeter linearity. In
addition, measurements of detection efficiency, hit multiplicity, and energy
shower profiles obtained during the exposure of small size prototypes to
radioactive source quanta, cosmic particles and accelerator beams are reported.
Eventually, the status of a large scale chamber (1{\times}1 m2) are also
presented with prospective towards the construction of a 1 m3 digital
calorimeter consisting of 40 such chambers.
-
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout,
with 1x1cm2 readout segmentation have been built and tested. Measurements in
Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the
prototypes gas gain versus pressure, gas temperature and amplification gap
thickness variations has been measured with an 55Fe source and a method for
temperature and pressure correction of data is presented. A stack of four
chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams
respectively. Measurements of response uniformity, detection efficiency and hit
multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital
readout electronics has been assembled and tested. The chamber layout and first
results are presented.