The precise value of the mean neutron lifetime, $\tau_n$, plays an important
role in nuclear and particle physics and cosmology. It is a key input for
predicting the ratio of protons to helium atoms in the primordial universe and
is used to search for new physics beyond the Standard Model of particle
physics. There is a 3.9 standard deviation discrepancy between $\tau_n$
measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2
s) and by counting surviving ultracold neutrons stored for different storage
times in a material trap (878.5$\pm$0.8 s). The experiment described here
eliminates loss mechanisms present in previous trap experiments by levitating
polarized ultracold neutrons above the surface of an asymmetric storage trap
using a repulsive magnetic field gradient so that the stored neutrons do not
interact with material trap walls and neutrons in quasi-stable orbits rapidly
exit the trap. As a result of this approach and the use of a new in situ
neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2
(sys) s) is the first modern measurement of $\tau_n$ that does not require
corrections larger than the quoted uncertainties.
-
Precision measurements of free neutron $\beta$-decay have been used to
precisely constrain our understanding of the weak interaction. However the
neutron Fierz interference term $b_n$, which is particularly sensitive to
Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded
measurement. Here we report the first direct constraints on this term, finding
$b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$,
consistent with the Standard Model. The uncertainty is dominated by absolute
energy reconstruction and the linearity of the beta spectrometer energy
response.
-
We describe a detection system designed for precise measurements of angular
correlations in neutron $\beta$ decay. The system is based on thick, large
area, highly segmented silicon detectors developed in collaboration with Micron
Semiconductor, Ltd. The prototype system meets specifications for $\beta$
electron detection with energy thresholds below 10 keV, energy resolution of
$\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector
pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science
Center, we have demonstrated the coincident detection of $\beta$ particles and
recoil protons from neutron $\beta$ decay. The fully instrumented detection
system will be implemented in the UCNB and Nab experiments, to determine the
neutron $\beta$ decay parameters $B$, $a$, and $b$.
-
The neutron lifetime is important in understanding the production of light
nuclei in the first minutes after the big bang and it provides basic
information on the charged weak current of the standard model of particle
physics. Two different methods have been used to measure the neutron lifetime:
disappearance measurements using bottled ultracold neutrons and decay rate
measurements using neutron beams. The best measurements using these two
techniques give results that differ by nearly 4 standard deviations. In this
paper we describe a new method for measuring surviving neutrons in neutron
lifetime measurements using bottled ultracold neutrons that provides better
characterization of systematic uncertainties and enables higher precision than
previous measurement techniques. We present results obtained using our method.
-
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated
using an imaging charge-coupled device (CCD) camera. A spatial resolution less
than 15 $\mu$m has been achieved, which is equivalent to an UCN energy
resolution below 2 pico-electron-volts through the relation $\delta E = m_0g
\delta x$. Here, the symbols $\delta E$, $\delta x$, $m_0$ and $g$ are the
energy resolution, the spatial resolution, the neutron rest mass and the
gravitational acceleration, respectively. A multilayer surface convertor
described previously is used to capture UCNs and then emits visible light for
CCD imaging. Particle identification and noise rejection are discussed through
the use of light intensity profile analysis. This method allows different types
of UCN spectroscopy and other applications.
-
A multilayer surface detector for ultracold neutrons (UCNs) is described. The
top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs.
The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is
sufficient to detect the charged particles from the $^{10}$B(n,$\alpha$)$^7$Li
neutron-capture reaction, while thin enough so that ample light due to $\alpha$
and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick
$^{10}$B layer gives high UCN detection efficiency, as determined by the mean
UCN kinetic energy, detector materials and others. Low background, including
negligible sensitivity to ambient neutrons, has also been verified through
pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B
detectors. This type of detector has been configured in different ways for UCN
flux monitoring, development of UCN guides and neutron lifetime research.
-
We present the status of current US experimental efforts to measure the
lifetime of the free neutron by the "beam" and "bottle" methods. BBN
nucleosynthesis models require accurate measurements with 1 second
uncertainties, which are currently feasible. For tests of physics beyond the
standard model, future efforts will need to achieve uncertainties well below 1
second. We outline paths achieve both.
-
It is generally accepted that the main cause of ultracold neutron (UCN)
losses in storage traps is the upscattering to the thermal energy range by
hydrogen adsorbed on the surface of the trap walls. However, the data on which
this conclusion is based are poor and contradictory. Here, we report a
measurement, performed at the Los Alamos National Laboratory UCN source, of the
average energy of the flux of upscattered neutrons after the interaction of UCN
with hydrogen bound in semicrystalline polymer PMP (tradename TPX),
[C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the
application of the neutron scattering law to UCN upscattered by bound hydrogen
in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux
average energy value of 26$\pm3$ meV in contradiction with previously reported
experimental values of 10 to 13 meV and in agreement with the theoretical
models of neutron heating implemented in the MCNP code.
-
The study of neutron cross sections for elements used as efficient
``absorbers'' of ultracold neutrons (UCN) is crucial for many precision
experiments in nuclear and particle physics, cosmology and gravity. In this
context, ``absorption'' includes both the capture and upscattering of neutrons
to the energies above the UCN energy region. The available data, especially for
hydrogen, do not agree between themselves or with the theory. In this report we
describe measurements performed at the Los Alamos National Laboratory UCN
facility of the UCN upscattering cross sections for vanadium and for hydrogen
in CH$_2$ using simultaneous measurements of the radiative capture cross
sections for these elements. We measured $\sigma_{up}=1972\pm130$ b for
hydrogen in CH$_2$, which is below theoretical expectations, and $\sigma_{up} <
25\pm9$ b for vanadium, in agreement with the expectation for the neutron
heating by thermal excitations in solids.
-
A new measurement of the neutron $\beta$-decay asymmetry $A_0$ has been
carried out by the UCNA collaboration using polarized ultracold neutrons (UCN)
from the solid deuterium UCN source at the Los Alamos Neutron Science Center
(LANSCE). Improvements in the experiment have led to reductions in both
statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm
stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector
coupling $\lambda \equiv g_A/g_V = -1.2756(30)$.
-
A precise measurement of the neutron decay $\beta$-asymmetry $A_0$ has been
carried out using polarized ultracold neutrons (UCN) from the pulsed spallation
UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data
obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm
0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the
axial-vector to vector weak coupling of the nucleon $g_A/g_V =
-1.27590_{-0.00445}^{+0.00409}$.
-
Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined
by the Fermi potential in material bottles, are playing an increasing role in
measurements of fundamental properties of the neutron. The ability to
manipulate UCN with material guides and bottles, magnetic fields, and gravity
can lead to experiments with lower systematic errors than have been obtained in
experiments with cold neutron beams. The UCN densities provided by existing
reactor sources limit these experiments. The promise of much higher densities
from solid deuterium sources has led to proposed facilities coupled to both
reactor and spallation neutron sources. In this paper we report on the
performance of a prototype spallation neutron-driven solid deuterium source.
This source produced bottled UCN densities of 145 +/-7 UCN/cm3, about three
times greater than the largest bottled UCN densities previously reported. These
results indicate that a production UCN source with substantially higher
densities should be possible.
-
We present the first measurements of the survival time of ultracold neutrons
(UCNs) in solid deuterium SD2. This critical parameter provides a fundamental
limitation to the effectiveness of superthermal UCN sources that utilize solid
ortho-deuterium as the source material. Superthermal UCN sources offer orders
of magnitude improvement in the available densities of UCNs, and are of great
importance to fundamental particle-physics experiments such as searches for a
static electric dipole moment and lifetime measurements of the free neutron.
These measurements are performed utilizing a SD2 source coupled to a spallation
source of neutrons, providing a demonstration of UCN production in this
geometry and permitting systematic studies of the influence of thermal
up-scatter and contamination with para-deuterium on the UCN survival time.