• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection (1707.01817)

    R. W. Pattie Jr., N. B. Callahan, C. Cude-Woods, E. R. Adamek, L. J. Broussard, S. M. Clayton, S. A. Currie, E. B. Dees, X. Ding, E. M. Engel, D. E. Fellers, W. Fox, K. P. Hickerson, M. A. Hoffbauer, A. T. Holley, A. Komives, C.-Y. Liu, S. W. T. MacDonald, M. Makela, C. L. Morris, J. D. Ortiz, J. Ramsey, D. J. Salvat, A. Saunders, S. J. Seestrom, E. I. Sharapov, S. K. Sjue, Z. Tang, J. Vanderwerp, B. Vogelaar, P. L. Walstrom, Z. Wang, W. Wei, H. L. Weaver, J. W. Wexler, T. L. Womack, A. R. Young, B. A. Zeck
    Feb. 7, 2018 hep-ex, nucl-ex, nucl-th
    The precise value of the mean neutron lifetime, $\tau_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $\tau_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $\tau_n$ that does not require corrections larger than the quoted uncertainties.
  • First direct constraints on Fierz interference in free neutron $\beta$ decay (1707.00776)

    K. P. Hickerson, X. Sun, Y. Bagdasarova, D. Bravo-Berguño, L. J. Broussard, M. A.-P. Brown, R. Carr, S. Currie, X. Ding, B. W. Filippone, A. García, P. Geltenbort, J. Hoagland, A. T. Holley, R. Hong, T. M. Ito, A. Knecht, C.-Y. Liu, J. L. Liu, M. Makela, R. R. Mammei, J. W. Martin, D. Melconian, M. P. Mendenhall, S. D. Moore, C. L. Morris, R. W. Pattie, Jr., A. Pérez Galván, R. Picker, M. L. Pitt, B. Plaster, J. C. Ramsey, R. Rios, A. Saunders, S. J. Seestrom, E. I. Sharapov, W. E. Sondheim, E. Tatar, R. B. Vogelaar, B. VornDick, C. Wrede, A. R. Young, B. A. Zeck
    July 8, 2017 nucl-ex
    ... ... ... ... ... ...
    Precision measurements of free neutron $\beta$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.
  • Detection System for Neutron $\beta$ Decay Correlations in the UCNB and Nab experiments (1607.02656)

    L. J. Broussard, B. A. Zeck, E. R. Adamek, S. Baeßler, N. Birge, M. Blatnik, J. D. Bowman, A. E. Brandt, M. Brown, J. Burkhart, N. B. Callahan, S. M. Clayton, C. Crawford, C. Cude-Woods, S. Currie, E. B. Dees, X. Ding, N. Fomin, E. Frlez, J. Fry, F. E. Gray, S. Hasan, K. P. Hickerson, J. Hoagland, A. T. Holley, T. M. Ito, A. Klein, H. Li, C.-Y. Liu, M. F. Makela, P. L. McGaughey, J. Mirabal-Martinez, C. L. Morris, J. D. Ortiz, R. W. Pattie Jr., S. I. Penttilä, B. Plaster, D. Počanić, J. C. Ramsey, A. Salas-Bacci, D. J. Salvat, A. Saunders, S. J. Seestrom, S. K. L. Sjue, A. P. Sprow, Z. Tang, R. B. Vogelaar, B. Vorndick, Z. Wang, W. Wei, J. Wexler, W. S. Wilburn, T. L. Womack, A. R. Young
    Jan. 7, 2017 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    We describe a detection system designed for precise measurements of angular correlations in neutron $\beta$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $\beta$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $\beta$ particles and recoil protons from neutron $\beta$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $\beta$ decay parameters $B$, $a$, and $b$.
  • A new method for measuring the neutron lifetime using an in situ neutron detector (1610.04560)

    C. L. Morris, E. R. Adamek, L. J. Broussard, N. B. Callahan, S. M. Clayton, C. Cude-Woods, S. A. Currie, X. Ding, W. Fox, K. P. Hickerson, A. T. Holley, A. Komives, C.-Y. Liu, M. Makela, R. W. Pattie Jr., J. Ramsey, D. J. Salvat, A. Saunders, S. J. Seestrom, E. I. Sharapov, S. K. Sjue, Z. Tang, J. Vanderwerp, B. Vogelaar, P. L. Walstrom, Z. Wang, Wanchun Wei, J. W. Wexler, T. L. Womack, A. R. Young, B. A. Zeck
    Oct. 14, 2016 nucl-ex, physics.ins-det
    The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.
  • Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy (1604.08292)

    Wanchun Wei, L. J. Broussard, M. A. Hoffbauer, M. Makela, C. L. Morris, Z. Tang, E. R. Adamek, N. B. Callahan, S. M. Clayton, C. Cude-Woods, S. Currie, E. B. Dees, X. Ding, P. Geltenbort, K. P. Hickerson, A. T. Holley, T. M. Ito, K. K. Leung, C.-Y. Liu, D. J. Morley, Jose D. Ortiz, R. W. Pattie, Jr., J. C. Ramsey, A. Saunders, S. J. Seestrom, E. I. Sharapov, S. K. Sjue, J. Wexler, T. L. Womack, A. R. Young, B. A. Zeck, Zhehui Wang
    May 12, 2016 physics.ins-det
    ... ... ... ... ... ...
    Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $\mu$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $\delta E = m_0g \delta x$. Here, the symbols $\delta E$, $\delta x$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
  • A multilayer surface detector for ultracold neutrons (1503.03424)

    Zhehui Wang, M. A. Hoffbauer, C. L. Morris, N. B. Callahan, E. R. Adamek, J. D. Bacon, M. Blatnik, A. E. Brandt, L. J. Broussard, S. M. Clayton, C. Cude-Woods, S. Currie, E. B. Dees, X. Ding, J. Gao, F. E. Gray, K. P. Hickerson, A. T. Holley, T. M. Ito, C.-Y. Liu, M. Makela, J. C. Ramsey, R. W. Pattie, Jr., D. J. Salvat, A. Saunders, D. W. Schmidt, R. K. Schulze, S. J. Seestrom, E. I. Sharapov, A. Sprow, Z. Tang, W. Wei, J. W. Wexler, T. L. Womack, A. R. Young, B. A. Zeck
    April 24, 2015 physics.ins-det
    ... ... ... ... ... ...
    A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$\alpha$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $\alpha$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
  • Determination of the Free Neutron Lifetime (1410.5311)

    J. David Bowman, L. J. Broussard, S. M. Clayton, M. S. Dewey, N. Fomin, K. B. Grammer, G. L. Greene, P. R. Huffman, A. T. Holley, G. L. Jones, C.-Y. Liu, M. Makela, M. P. Mendenhall, C. L. Morris, J. Mulholland, K. M. Nollett, R. W. Pattie, Jr., S. Penttila, M. Ramsey-Musolf, D. J. Salvat, A. Saunders, S. J. Seestrom, W. M. Snow, A. Steyerl, F. E. Wietfeldt, A. R. Young, A. T. Yue
    Oct. 20, 2014 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.
  • The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$ (1308.2710)

    E. I. Sharapov, C. L. Morris, M. Makela, A. Saunders, Evan R. Adamek, L. J. Broussard, C. B. Cude-Woods, Deion E Fellers, Peter Geltenbort, M. Hartl, S. I. Hasan, K. P. Hickerson, G. Hogan, A. T. Holley, C. M. Lavelle, Chen-Yu Liu, M. P. Mendenhall, J. Ortiz, R. W. Pattie Jr., J. Ramsey, D. J. Salvat, S. J. Seestrom, E. Shaw, Sky Sjue, W. E. Sondheim, B. VornDick, Z. Wang, T. L. Womack, A. R. Young, Bryan A. Zeck, D. G. Phillips
    Aug. 12, 2013 nucl-ex, cond-mat.mtrl-sci
    ... ... ... ... ... ...
    It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.
  • Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium (1306.1261)

    E. I. Sharapov, C. L. Morris, M. Makela, A. Saunders, Evan R. Adamek, Yelena Bagdasarova, L. J. Broussard, C. B. Cude-Woods, Deon E Fellers, Peter Geltenbort, S. I. Hasan, K. P. Hickerson, G. Hogan, A. T. Holley, Chen-Yu Liu, M. P. Mendenhall, J. Ortiz, R. W. Pattie Jr., D. G. Phillips, J. Ramsey, D. J. Salvat, S. J. Seestrom, E. Shaw, Sky Sjue, W. E. Sondheim, B. VornDick, Z. Wang, T. L. Womack, A. R. Young, B. A. Zeck
    June 5, 2013 nucl-ex
    ... ... ... ... ... ...
    The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $\sigma_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $\sigma_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.
  • Precision Measurement of the Neutron Beta-Decay Asymmetry (1210.7048)

    M. P. Mendenhall, R. W. Pattie Jr, Y. Bagdasarova, D. B. Berguno, L. J. Broussard, R. Carr, S. Currie, X. Ding, B. W. Filippone, A. García, P. Geltenbort, K. P. Hickerson, J. Hoagland, A. T. Holley, R. Hong, T. M. Ito, A. Knecht, C.-Y. Liu, J. L. Liu, M. Makela, R. R. Mammei, J. W. Martin, D. Melconian, S. D. Moore, C. L. Morris, A. Pérez Galván, R. Picker, M. L. Pitt, B. Plaster, J. C. Ramsey, R. Rios, A. Saunders, S. J. Seestrom, E. I. Sharapov, W. E. Sondheim, E. Tatar, R. B. Vogelaar, B. VornDick, C. Wrede, A. R. Young, B. A. Zeck
    Feb. 19, 2013 nucl-ex
    ... ... ... ... ... ...
    A new measurement of the neutron $\beta$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $\lambda \equiv g_A/g_V = -1.2756(30)$.
  • Determination of the Axial-Vector Weak Coupling Constant with Ultracold Neutrons (1007.3790)

    UCNA Collaboration: J. Liu, M. P. Mendenhall, A. T. Holley, H. O. Back, T. J. Bowles, L. J. Broussard, R. Carr, S. Clayton, S. Currie, B. W. Filippone, A. Garcia, P. Geltenbort, K. P. Hickerson, J. Hoagland, G. E. Hogan, B. Hona, T. M. Ito, C.-Y. Liu, M. Makela, R. R. Mammei, J. W. Martin, D. Melconian, C. L. Morris, R. W. Pattie Jr., A. Perez Galvan, M. L. Pitt, B. Plaster, J. C. Ramsey, R. Rios, R. Russell, A. Saunders, S. J. Seestrom, W. E. Sondheim, E. Tatar, R. B. Vogelaar, B. VornDick, C. Wrede, H. Yan, A. R. Young
    Sept. 25, 2010 hep-ex, nucl-ex
    ... ... ... ... ... ...
    A precise measurement of the neutron decay $\beta$-asymmetry $A_0$ has been carried out using polarized ultracold neutrons (UCN) from the pulsed spallation UCN source at the Los Alamos Neutron Science Center (LANSCE). Combining data obtained in 2008 and 2009, we report $A_0 = -0.11966 \pm 0.00089_{-0.00140}^{+0.00123}$, from which we determine the ratio of the axial-vector to vector weak coupling of the nucleon $g_A/g_V = -1.27590_{-0.00445}^{+0.00409}$.
  • Demonstration of a solid deuterium source of ultra-cold neutrons (nucl-ex/0312021)

    A. Saunders, J. M. Anaya, T. J. Bowles, B. W. Filippone, P. Geltenbort, R. E. Hill, M. Hino, S. Hoedl, G. E. Hogan, T. M. Ito, K. W. Jones, T. Kawai, K. Kirch, S. K. Lamoreaux, C.-Y. Liu, M. Makela, L. J. Marek, J. W. Martin, C. L. Morris, R. N. Mortensen, A. Pichlmaier, S. J. Seestrom, A. Serebrov, D. Smith, W. Teasdale, B. Tipton, R. B. Vogelaar, A. R. Young, J. Yuan
    Dec. 18, 2003 nucl-ex
    Ultra-cold neutrons (UCN), neutrons with energies low enough to be confined by the Fermi potential in material bottles, are playing an increasing role in measurements of fundamental properties of the neutron. The ability to manipulate UCN with material guides and bottles, magnetic fields, and gravity can lead to experiments with lower systematic errors than have been obtained in experiments with cold neutron beams. The UCN densities provided by existing reactor sources limit these experiments. The promise of much higher densities from solid deuterium sources has led to proposed facilities coupled to both reactor and spallation neutron sources. In this paper we report on the performance of a prototype spallation neutron-driven solid deuterium source. This source produced bottled UCN densities of 145 +/-7 UCN/cm3, about three times greater than the largest bottled UCN densities previously reported. These results indicate that a production UCN source with substantially higher densities should be possible.
  • Measurements of ultracold neutron lifetimes in solid deuterium (nucl-ex/0109020)

    C. L. Morris, J. M. Anaya, T. J. Bowles, B. W. Filippone, P. Geltenbort, R. E. Hill, M. Hino, S. Hoedl, G. E. Hogan, T. M. Ito, T. Kawai, K. Kirch, S. K. Lamoreaux, C.-Y. Liu, M. Makela, L. J. Marek, J. W. Martin, R. N. Mortensen, A. Pichlmaier, A. Saunders, S. J. Seestrom, D. Smith, W. Teasdale, B. Tipton, M. Utsuro, A. R. Young,J. Yuan
    Sept. 28, 2001 nucl-ex
    We present the first measurements of the survival time of ultracold neutrons (UCNs) in solid deuterium SD2. This critical parameter provides a fundamental limitation to the effectiveness of superthermal UCN sources that utilize solid ortho-deuterium as the source material. Superthermal UCN sources offer orders of magnitude improvement in the available densities of UCNs, and are of great importance to fundamental particle-physics experiments such as searches for a static electric dipole moment and lifetime measurements of the free neutron. These measurements are performed utilizing a SD2 source coupled to a spallation source of neutrons, providing a demonstration of UCN production in this geometry and permitting systematic studies of the influence of thermal up-scatter and contamination with para-deuterium on the UCN survival time.