-
Many rare event searches including dark matter direct detection and
neutrinoless double beta decay experiments take advantage of the high VUV
reflective surfaces made from polytetrafluoroethylene (PTFE) reflector
materials to achieve high light collection efficiency in their detectors. As
the detectors have grown in size over the past decade, there has also been an
increased need for ever thinner detector walls without significant loss in
reflectance to reduce dead volumes around active noble liquids, outgassing, and
potential backgrounds. We report on the experimental results to measure the
dependence of the reflectance on thickness of two PTFE samples at wavelengths
near 178 nm. No change in reflectance was observed as the thickness of a
cylindrically shaped PTFE vessel immersed in liquid xenon was varied between 1
mm and 9.5 mm.
-
We present the results of a search for WIMPs from the commissioning run of
the PandaX-II experiment located at the China Jinping underground Laboratory. A
WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken,
while its dominant $^{85}$Kr background was used as the electron recoil
calibration. No WIMP candidates are identified, and a 90\% upper limit is set
on the spin-independent elastic WIMP-nucleon cross section with a lowest
excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of
44.7~GeV/c$^2$.
-
Cryogenic liquids, particularly liquid xenon and argon, are of interest as
detector media for experiments in nuclear and particle physics. Here we present
a new detector diagnostic technique using piezoelectric sensors to detect
bubbling of the liquid. Bubbling can indicate locations of excess heat
dissipation e.g., in immersed electronics. They can also interfere with normal
event evolution by scattering of light or by interrupting the drift of
ionization charge. In our test apparatus, four sensors are placed in the vacuum
space of a double-walled dewar of liquid nitrogen and used to detect and locate
a source of bubbling inside the liquid volume. Utilizing the differences in
transmitted frequencies through the different media present in the experiment,
we find that sound traveling in a direct path from the source to the sensor can
be isolated with appropriate filtering. The location of the source is then
reconstructed using the time difference of arrivals (TDOA) information. The
reconstruction algorithm is shown to have a 95.8% convergence rate and
reconstructed positions are self-consistent to an average +/-0.5cm around the
mean in x, y, and z. Systematic effects are observed to cause errors in
reconstruction when bubbles occur very close to the surfaces of the liquid
volume.
-
We report the results of a weakly-interacting massive particle (WIMP) dark
matter search using the full 80.1\;live-day exposure of the first stage of the
PandaX experiment (PandaX-I) located in the China Jin-Ping Underground
Laboratory. The PandaX-I detector has been optimized for detecting low-mass
WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid
xenon target mass of 54.0\,kg, no significant excess event were found above the
expected background. A profile likelihood analysis confirms our earlier finding
that the PandaX-I data disfavor all positive low-mass WIMP signals reported in
the literature under standard assumptions. A stringent bound on the low mass
WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon
detectors can be competitive for low-mass WIMP searches.
-
We report on the first dark-matter (DM) search results from PandaX-I, a low
threshold dual-phase xenon experiment operating at the China Jinping
Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of
exposure, no DM particle candidate event was found. This result sets a
stringent limit for low-mass DM particles and disfavors the interpretation of
previously-reported positive experimental results. The minimum upper limit,
$3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar
DM-particle-nucleon scattering cross section is obtained at a DM-particle mass
of 49\,GeV/c$^2$ at 90\% confidence level.