Hitomi (ASTRO-H) carries two Hard X-ray Telescopes (HXTs) that can focus
X-rays up to 80 keV. Combined with the Hard X-ray Imagers (HXIs) that detect
the focused X-rays, imaging spectroscopy in the high-energy band from 5 keV to
80 keV is made possible. We studied characteristics of HXTs after the launch
such as the encircled energy function (EEF) and the effective area using the
data of a Crab observation. The half power diameters (HPDs) in the 5--80 keV
band evaluated from the EEFs are 1.59 arcmin for HXT-1 and 1.65 arcmin for
HXT-2. Those are consistent with the HPDs measured with ground experiments when
uncertainties are taken into account. We can conclude that there is no
significant change in the characteristics of the HXTs before and after the
launch. The off-axis angle of the aim point from the optical axis is evaluated
to be less than 0.5 arcmin for both HXT-1 and HXT-2. The best-fit parameters
for the Crab spectrum obtained with the HXT-HXI system are consistent with the
canonical values.
-
We describe the in-orbit performance of the soft X-ray imaging system
consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi.
Verification and calibration of imaging and spectroscopic performance are
carried out making the best use of the limited data of less than three weeks.
Basic performance including a large field of view of 38'x38' is verified with
the first light image of the Perseus cluster of galaxies. Amongst the small
number of observed targets, the on-minus-off pulse image for the out-of-time
events of the Crab pulsar enables us to measure a half power diameter of the
telescope as about 1.3'. The average energy resolution measured with the
onboard calibration source events at 5.89 keV is 179 pm 3 eV in full width at
half maximum. Light leak and cross talk issues affected the effective exposure
time and the effective area, respectively, because all the observations were
performed before optimizing an observation schedule and parameters for the dark
level calculation. Screening the data affected by these two issues, we measure
the background level to be 5.6x10^{-6} counts s^{-1} arcmin^{-2} cm^{-2} in the
energy band of 5-12 keV, which is seven times lower than that of the Suzaku
XIS-BI.
-
Using the wealth of ~24 yr multiband data, we present an in-depth study of
the star-spot cycles, surface differential rotations (SDR), optical flares,
evolution of star-spot distributions, and coronal activities on the surface of
young, single, main-sequence, ultrafast rotator (UFR) LO Peg. From the
long-term V -band photometry, we derive rotational period of LO Peg to be
0.4231 +/- 0.0001 d. Using the seasonal variations on the rotational period,
the SDR pattern is investigated, and shows a solar-like pattern of SDR. A
cyclic pattern with period of ~2.7 yr appears to be present in rotational
period variation. During the observations, 20 optical flares are detected with
a flare frequency of 1 flare per two days and with flare energy of 10^{31-34}
erg. The surface coverage of cool spots is found to be in the range of 9-26 per
cent. It appears that the high- and low-latitude spots are interchanging their
positions. Quasi-simultaneous observations in X-ray, UV, and optical
photometric bands show a signature of an excess of X-ray and UV activities in
spotted regions.
-
X-ray polarimetry promises to give qualitatively new information about
high-energy astrophysical sources, such as binary black hole systems,
micro-quasars, active galactic nuclei, neutron stars, and gamma-ray bursts. We
designed, built and tested a X-ray polarimeter, X-Calibur, to be used in the
focal plane of the balloon-borne InFOCuS grazing incidence X-ray telescope.
X-Calibur combines a low-Z scatterer with a CZT detector assembly to measure
the polarization of 20-80keV X-rays making use of the fact that polarized
photons scatter preferentially perpendicular to the electric field orientation.
X-Calibur achieves a high detection efficiency of ~80%. The X-Calibur detector
assembly is completed, tested, and fully calibrated. The response to a
polarized X-ray beam was measured successfully at the Cornell High Energy
Synchrotron Source. This paper describes the design, calibration and
performance of the X-Calibur polarimeter. In principle, a similar space-borne
scattering polarimeter could operate over the broader 2-100keV energy band.
-
X-ray polarimetry promises to give new information about high-energy
astrophysical sources, such as binary black hole systems, micro-quasars, active
galactic nuclei, and gamma-ray bursts. We designed, built and tested a hard
X-ray polarimeter X-Calibur to be used in the focal plane of the InFOCuS
grazing incidence hard X-ray telescope. X-Calibur combines a low-Z Compton
scatterer with a CZT detector assembly to measure the polarization of 10-80 keV
X-rays making use of the fact that polarized photons Compton scatter
preferentially perpendicular to the electric field orientation. X-Calibur
achieves a high detection efficiency of order unity.
-
X-ray polarimetry promises to give qualitatively new information about
high-energy astrophysical sources, such as binary black hole systems,
micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built
and tested a hard X-ray polarimeter X-Calibur to be used in the focal plane of
the InFOCuS grazing incidence hard X-ray telescope. X-Calibur combines a low-Z
Compton scatterer with a CZT detector assembly to measure the polarization of
10-80 keV X-rays making use of the fact that polarized photons Compton scatter
preferentially perpendicular to the electric field orientation. X-Calibur
achieves a high detection efficiency of order unity.
-
Since it is not possible to predict when a Gamma-Ray Burst (GRB) will occur
or when Active Galactic Nucleus (AGN) flaring activity starts,
follow-up/monitoring ground telescopes must be located as uniformly as possible
all over the world in order to collect data simultaneously with Fermi and Swift
detections. However, there is a distinct gap in follow-up coverage of
telescopes in the eastern U.S. region based on the operations of Swift.
Motivated by this fact, we have constructed a 14" fully automated optical
robotic telescope, Goddard Robotic Telescope (GRT), at the Goddard Geophysical
and Astronomical Observatory. The aims of our robotic telescope are 1) to
follow-up Swift/Fermi GRBs and 2) to perform the coordinated optical
observations of Fermi Large Area Telescope (LAT) AGN. Our telescope system
consists of off-the-shelf hardware. With the focal reducer, we are able to
match the field of view of Swift narrow instruments (20' x 20'). We started
scientific observations in mid-November 2008 and GRT has been fully remotely
operated since August 2009. The 3 sigma upper limit in a 30-second exposure in
the R filter is ~15.4 mag; however, we can reach to ~18 mag in a 600-second
exposures. Due to the weather condition at the telescope site, our observing
efficiency is 30-40% on average.
-
We present the catalog of sources detected in the first 22 months of data
from the hard X-ray survey (14--195 keV) conducted with the BAT coded mask
imager on the \swift satellite. The catalog contains 461 sources detected above
the 4.8 sigma level with BAT. High angular resolution X-ray data for every
source from Swift XRT or archival data have allowed associations to be made
with known counterparts in other wavelength bands for over 97% of the
detections, including the discovery of ~30 galaxies previously unknown as AGN
and several new Galactic sources. A total of 266 of the sources are associated
with Seyfert galaxies (median redshift z ~ 0.03) or blazars, with the majority
of the remaining sources associated with X-ray binaries in our Galaxy. This
ongoing survey is the first uniform all sky hard X-ray survey since HEAO-1 in
1977.
Since the publication of the 9-month BAT survey we have increased the number
of energy channels from 4 to 8 and have substantially increased the number of
sources with accurate average spectra. The BAT 22-month catalog is the product
of the most sensitive all-sky survey in the hard X-ray band, with a detection
sensitivity (4.8 sigma) of 2.2e-11 erg/cm2/s (1 mCrab) over most of the sky in
the 14--195 keV band.
-
The CZT detector on the Infocus hard X-ray telescope is a pixellated
solid-state device capable of imaging spectroscopy by measuring the position
and energy of each incoming photon. The detector sits at the focal point of an
8m focal length multilayered grazing incidence X-ray mirror which has
significant effective area between 20--40 keV. The detector has an energy
resolution of 4.0keV at 32keV, and the Infocus telescope has an angular
resolution of 2.2 arcminute and a field of view of about 10 arcminutes. Infocus
flew on a balloon mission in July 2001 and observed Cygnus X-1. We present
results from laboratory testing of the detector to measure the uniformity of
response across the detector, to determine the spectral resolution, and to
perform a simple noise decomposition. We also present a hard X-ray spectrum and
image of Cygnus X-1, and measurements of the hard X-ray CZT background obtained
with the SWIN detector on Infocus.