The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum
efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and
is of significant interest for future dark matter and neutrino experiments
where high signal yields are needed.
We report on the methods developed for in-situ characterization and
monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of
typical measured single-photoelectron charge distributions, correlated noise
(afterpulsing), dark noise, double, and late pulsing characteristics. The
characterization is performed during the detector commissioning phase using
laser light injected through a light diffusing sphere and during normal
detector operation using LED light injected through optical fibres.
-
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
-
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has
been designed for a direct detection search for particle dark matter using a
single-phase liquid argon target. The projected cross section sensitivity for
DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$
WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the
physical properties and construction of the DEAP-3600 detector.