-
The strong coupling constant $\alpha_s(M_Z)$ is determined from inclusive jet
and dijet cross sections in neutral-current deep-inelastic $ep$ scattering
(DIS) measured at HERA by the H1 collaboration using next-to-next-to-leading
order (NNLO) QCD predictions. The dependence of the NNLO predictions and of the
resulting value of $\alpha_s(M_Z)$ at the $Z$-boson mass $m_Z$ are studied as a
function of the choice of the renormalisation and factorisation scales. Using
inclusive jet and dijet data together, the strong coupling constant is
determined to be $\alpha_s(M_Z)=0.1157\,(20)_{\rm exp}\,(29)_{\rm th}$.
Complementary, \asmz\ is determined together with parton distribution functions
of the proton (PDFs) from jet and inclusive DIS data measured by the H1
experiment. The value $\alpha_s(M_Z)=0.1142\,(28)_{\rm tot}$ obtained is
consistent with the determination from jet data alone. The impact of the jet
data on the PDFs is studied. The running of the strong coupling is tested at
different values of the renormalisation scale and the results are found to be
in agreement with expectations.
-
Low Gain Avalanche Detectors (LGADs) are silicon sensors with a built-in
charge multiplication layer providing a gain of typically 10 to 50. Due to the
combination of high signal-to-noise ratio and short rise time, thin LGADs
provide good time resolutions.
LGADs with an active thickness of about 45 $\mu$m were produced at CNM
Barcelona. Their gains and time resolutions were studied in beam tests for two
different multiplication layer implantation doses, as well as before and after
irradiation with neutrons up to $10^{15}$ n$_{eq}$/cm$^2$.
The gain showed the expected decrease at a fixed voltage for a lower initial
implantation dose, as well as for a higher fluence due to effective acceptor
removal in the multiplication layer. Time resolutions below 30 ps were obtained
at the highest applied voltages for both implantation doses before irradiation.
Also after an intermediate fluence of $3\times10^{14}$ n$_{eq}$/cm$^2$, similar
values were measured since a higher applicable reverse bias voltage could
recover most of the pre-irradiation gain. At $10^{15}$ n$_{eq}$/cm$^2$, the
time resolution at the maximum applicable voltage of 620 V during the beam test
was measured to be 57 ps since the voltage stability was not good enough to
compensate for the gain layer loss. The time resolutions were found to follow
approximately a universal function of gain for all implantation doses and
fluences.
-
The ATLAS Roman Pot system is designed to determine the total proton-proton
cross-section as well as the luminosity at the Large Hadron Collider (LHC) by
measuring elastic proton scattering at very small angles. The system is made of
four Roman Pot stations, located in the LHC tunnel in a distance of about 240~m
at both sides of the ATLAS interaction point. Each station is equipped with
tracking detectors, inserted in Roman Pots which approach the LHC beams
vertically. The tracking detectors consist of multi-layer scintillating fibre
structures readout by Multi-Anode-Photo-Multipliers.
-
The ATLAS Forward Proton (AFP) detector is intended to measure protons
scattered at small angles from the ATLAS interaction point. To this end, a
combination of 3D Silicon pixel tracking modules and Quartz-Cherenkov
time-of-flight (ToF) detectors is installed 210m away from the interaction
point at both sides of ATLAS. Beam tests with an AFP prototype detector
combining tracking and timing sub-detectors and a common readout have been
performed at the CERN-SPS test-beam facility in November 2014 and September
2015 to complete the system integration and to study the detector performance.
The successful tracking-timing integration was demonstrated. Good tracker hit
efficiencies above 99.9% at a sensor tilt of 14{\deg}, as foreseen for AFP,
were observed. Spatial resolutions in the short pixel direction with 50 {\mu}m
pitch of 5.5 +/- 0.5 {\mu}m per pixel plane and of 2.8 +/- 0.5 {\mu}m for the
full four-plane tracker at 14{\deg} were found, largely surpassing the AFP
requirement of 10 {\mu}m. The timing detector showed also good hit efficiencies
above 99%, and a full-system time resolution of 35 +/- 6 ps was found for the
ToF prototype detector with two Quartz bars in-line (half the final AFP size)
without dedicated optimisation, fulfilling the requirements for initial
low-luminosity AFP runs.
-
A detailed study is presented of the expected performance of the ATLAS
detector. The reconstruction of tracks, leptons, photons, missing energy and
jets is investigated, together with the performance of b-tagging and the
trigger. The physics potential for a variety of interesting physics processes,
within the Standard Model and beyond, is examined. The study comprises a series
of notes based on simulations of the detector and physics processes, with
particular emphasis given to the data expected from the first years of
operation of the LHC at CERN.
-
We study the space-time symmetries and transformation properties of the
non-commutative U(1) gauge theory, by using Noether charges. We carry out our
analysis by keeping an open view on the possible ways $\theta^{\mu \nu}$ could
transform. We conclude that $\theta^{\mu \nu}$ cannot transform under any
space-time transformation since the theory is not invariant under the conformal
transformations, with the only exception of space-time translations. The same
analysis applies to other gauge groups.
-
There exist two versions of the covariant Schwinger term in the literature.
They only differ by a sign. However, we shall show that this is an essential
difference. We shall carefully (taking all signs into account) review the
existing quantum field theoretical computations for the covariant Schwinger
term in order to determine the correct expression.