• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • The Herschel-SPIRE instrument and its in-flight performance (1005.5123)

    M. J. Griffin, A. Abergel, A. Abreu, P. A. R. Ade, P. André, J.-L. Augueres, T. Babbedge, Y. Bae, T. Baillie, J.-P. Baluteau, M. J. Barlow, G. Bendo, D. Benielli, J. J. Bock, P. Bonhomme, D. Brisbin, C. Brockley-Blatt, M. Caldwell, C. Cara, N. Castro-Rodriguez, R. Cerulli, P. Chanial, S. Chen, E. Clark, D. L. Clements, L. Clerc, J. Coker, D. Communal, L. Conversi, P. Cox, D. Crumb, C. Cunningham, F. Daly, G. R. Davis, P. De Antoni, J. Delderfield, N. Devin, A. Di Giorgio, I. Didschuns, K. Dohlen, M. Donati, A. Dowell, C. D. Dowell, L. Duband, L. Dumaye, R. J. Emery, M. Ferlet, D. Ferrand, J. Fontignie, M. Fox, A. Franceschini, M. Frerking, T. Fulton, J. Garcia, R. Gastaud, W. K. Gear, J. Glenn, A. Goizel, D. K. Griffin, T. Grundy, S. Guest, L. Guillemet, P. C. Hargrave, M. Harwit, P. Hastings, E. Hatziminaoglou, M. Herman, B. Hinde, V. Hristov, M. Huang, P. Imhof, K. J. Isaak, U. Israelsson, R. J. Ivison, D. Jennings, B. Kiernan, K. J. King, A. E. Lange, W. Latter, G. Laurent, P. Laurent, S. J. Leeks, E. Lellouch, L. Levenson, B. Li, J. Li, J. Lilienthal, T. Lim, J. Liu, N. Lu, S. Madden, G. Mainetti, P. Marliani, D. McKay, K. Mercier, S. Molinari, H. Morris, H. Moseley, J. Mulder, M. Mur, D. A. Naylor, H. Nguyen, B. O'Halloran, S. Oliver, G. Olofsson, H.-G. Olofsson, R. Orfei, M. J. Page, I. Pain, P. Panuzzo, A. Papageorgiou, G. Parks, P. Parr-Burman, A. Pearce, C. Pearson, I. Pérez-Fournon, F. Pinsard, G. Pisano, J. Podosek, M. Pohlen, E. T. Polehampton, D. Pouliquen, D. Rigopoulou, D. Rizzo, I. G. Roseboom, H. Roussel, M. Rowan-Robinson, B. Rownd, P. Saraceno, M. Sauvage, R. Savage, G. Savini, E. Sawyer, C. Scharmberg, D. Schmitt, N. Schneider, B. Schulz, A. Schwartz, R. Shafer, D. L. Shupe, B. Sibthorpe, S. Sidher, A. Smith, A. J. Smith, D. Smith, L. Spencer, B. Stobie, R. Sudiwala, K. Sukhatme, C. Surace, J. A. Stevens, B. M. Swinyard, M. Trichas, T. Tourette, H. Triou, S. Tseng, C. Tucker, A. Turner, M. Vaccari, I. Valtchanov, L. Vigroux, E. Virique, G. Voellmer, H. Walker, R. Ward, T. Waskett, M. Weilert, R. Wesson, G. J. White, N. Whitehouse, C. D. Wilson, B. Winter, A. L. Woodcraft, G. S. Wright, C. K. Xu, A. Zavagno, M. Zemcov, L. Zhang, E. Zonca
    May 27, 2010 astro-ph.IM
    ... ... ... ... ... ...
    The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
  • Young Stellar Objects and Triggered Star Formation in the Vulpecula OB Association (1003.0866)

    N. Billot, A. Noriega-Crespo, S. Carey, S. Guieu, S. Shenoy, R. Paladini, W. Latter
    March 3, 2010 astro-ph.GA
    ... ... ... ... ... ...
    The Vulpecula OB association, VulOB1, is a region of active star formation located in the Galactic plane at 2.3 kpc from the Sun. Previous studies suggest that sequential star formation is propagating along this 100 pc long molecular complex. In this paper, we use Spitzer MIPSGAL and GLIMPSE data to reconstruct the star formation history of VulOB1, and search for signatures of past triggering events. We make a census of Young Stellar Objects (YSO) in VulOB1 based on IR color and magnitude criteria, and we rely on the properties and nature of these YSOs to trace recent episodes of massive star formation. We find 856 YSO candidates, and show that the evolutionary stage of the YSO population in VulOB1 is rather homogeneous - ruling out the scenario of propagating star formation. We estimate the current star formation efficiency to be ~8 %. We also report the discovery of a dozen pillar-like structures, which are confirmed to be sites of small scale triggered star formation.
  • The Dark Side of Reionization: Probing Cooling in the Early Universe (0903.1839)

    P. N. Appleton, L. Armus, A. Blain, F. Boulanger, M. Brandford, V. Bromm, C. Carilli, R-R. Chary, E. Egami, D. Frayer, M. Harwitt, G. Helou, M. Lacy, W. Latter, D. Leisawitz, C. Lonsdale, A. Ormont, P. Ogle, M. Ricotti, A. Wootten
    March 10, 2009 astro-ph.CO
    Probing the growth of structure from the epoch of hydrogen recombination to the formation of the first stars and galaxies is one of the most important uncharted areas of observational cosmology. Far-IR spectroscopy covering $\lambda$ 100-500 microns from space, and narrow partial transmission atmospheric bands available from the ground, opens up the possibility of probing the molecular hydrogen and metal fine-structure lines from primordial clouds from which the first stars and galaxies formed at 6 < z $<$ 15. Building on Spitzer observations of unexpectedly powerful H2 emission from shocks, we argue that next-generation far-IR space telescopes may open a new window into the main cloud cooling processes and feedback effects which characterized this vital, but unexplored epoch. Without this window, we are essential blind to the dominant cloud cooling which inevitably led to star formation and cosmic reionization.
  • The nature of luminous X-ray sources with mid-infrared counterparts (astro-ph/0406153)

    A. Alonso-Herrero, P. G. Perez-Gonzalez, J. Rigby, G. H. Rieke, E. Le Floc'h, P. Barmby, M. J. Page, C. Papovich, H. Dole, E. Egami, J.-S. Huang, D. Rigopoulou, D. Cristobal-Hornillos, C. Eliche-Moral, M. Balcells, M. Prieto, P. Erwin, C. W. Engelbracht, K. D. Gordon, M. Werner, S. P. Willner, G. G. Fazio, D. Frayer, D. Hines, D. Kelly, W. Latter, K. Misselt, S. Miyazaki, J. Morrison, M. J. Rieke, G. Wilson
    June 7, 2004 astro-ph
    We investigate the luminous X-ray sources in the Lockman Hole (LH) and the Extended Groth Strip (EGS) detected at 24microns using MIPS and also with IRAC on board Spitzer. We assemble optical/infrared spectral energy distributions (SEDs) for 45 X-ray/24micron sources in the EGS and LH. Only about 1/4 of the hard X-ray/24micron sources show pure type 1 AGN SEDs. More than half of the X-ray/24micron sources have stellar-emission-dominated or obscured SEDs, similar to those of local type 2 AGN and spiral/starburst galaxies. One-third of the sources detected in hard X-rays do not have a 24micron counterpart. Two such sources in the LH have SEDs resembling those of S0/elliptical galaxies. The broad variety of SEDs in the optical-to-Spitzer bands of X-ray selected AGN means that AGN selected according to the behavior in the optical/infrared will have to be supplemented by other kinds of data (e.g., X-ray) to produce unbiased samples of AGN.