• The gyrotron is the high power millimeter wave source in the electron cyclotron resonance heating system for the tokamak. The cathode power supply is one of the most important ancillary devices for gyrotron. Some interesting transient phenomena about the cathode voltage and the cathode current was found in the gyrotron operation in the electron cyclotron resonance heating system for the Experimental Advanced Superconducting Tokamak. The cathode voltage drops to about 10% of the original value by about 90 {\mu}s in the overcurrent case, which is much longer than the 25 {\mu}s in the normal case. In order to explain these phenomena, an equivalent circuit model of the magnetron injection gun was proposed. The equivalent circuit is composed of parallel resistors and capacitors, and it can explain the test results very well. Using the equivalent circuit model to analyze gyrotrons may become an effective means of developing and operating an electron cyclotron heating system.
  • A coupling tunable D-band directional coupler is designed based on a novel coupling grid structure proposed in this letter. The designed directional coupler has excellent performance with ultra-wideband. The coupling can be tuned from -28.2 dB to -33.2 dB at 140 GHz by changing the angle of the coupling grid, and the dynamic range of the coupling is about 5 dB. The return loss is smaller than -15 dB in the whole D-band from 110 GHz to 170 GHz. A 3-dB coupler use the similar coupling structure is also designed. The coupling is 3.3144 dB at the center frequency of 140 GHz.
  • In this paper, an overcurrent protection system is designed to ensure the safety of the gyrotrons in the EAST ECRH system. Two overcurrent protection systems were established, a fast one and a slow one. The fast one uses the current transformers as the current sensors. The models of the current transformers and the superconducting magnet were built to analyze the effect of the environmental magnetic field on the current transformers using FI method. The analysis results show that the magnetic induction at the position near the current transformers must less than 0.002 T, i.e., the current transformers should be placed at a distance greater than 2.2 meters from the magnet center to ensure its normal work. The slow one uses the shunt to monitor the currents. An anti-fuse FPGA and a timer is used to realize the signal processing in the fast protection circuit and the slow protection circuit respectively. The response time of the fast protection circuit is less than 100 ns, and the response time of the slow protection circuit is less than 31 {\mu}s.
  • In this paper, the calorimetric power measurement method for electron cyclotron resonance heating system on EAST are presented. This method requires measurement of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature is controlled to be stable to get more accurate results. The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. A novel temperature calibration method is proposed also. This kind of calibration method is accurate and effective, and can be easily implemented.