The next-generation Enriched Xenon Observatory (nEXO) is a proposed
experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in
$^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years
using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time
projection chamber. This improvement of two orders of magnitude in sensitivity
over current limits is obtained by a significant increase of the $^{136}$Xe
mass, the monolithic and homogeneous configuration of the active medium, and
the multi-parameter measurements of the interactions enabled by the time
projection chamber. The detector concept and anticipated performance are
presented based upon demonstrated realizable background rates.
-
A new design for the anode of a time projection chamber, consisting of a
charge-detecting "tile", is investigated for use in large scale liquid xenon
detectors. The tile is produced by depositing 60 orthogonal metal
charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm}
fused-silica wafer. These charge tiles may be employed by large detectors, such
as the proposed tonne-scale nEXO experiment to search for neutrinoless
double-beta decay. Modular by design, an array of tiles can cover a sizable
area. The width of each strip is small compared to the size of the tile, so a
Frisch grid is not required. A grid-less, tiled anode design is beneficial for
an experiment such as nEXO, where a wire tensioning support structure and
Frisch grid might contribute radioactive backgrounds and would have to be
designed to accommodate cycling to cryogenic temperatures. The segmented anode
also reduces some degeneracies in signal reconstruction that arise in
large-area crossed-wire time projection chambers. A prototype tile was tested
in a cell containing liquid xenon. Very good agreement is achieved between the
measured ionization spectrum of a $^{207}$Bi source and simulations that
include the microphysics of recombination in xenon and a detailed modeling of
the electrostatic field of the detector. An energy resolution $\sigma/E$=5.5\%
is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only
resolution reported in literature for liquid xenon at 936~V/\si{cm}.
-
Alpha decays in the EXO-200 detector are used to measure the fraction of
charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from
alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid
xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$
of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral.
The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in
LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of
$^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The
average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer
drift times. Initially the ions have a mobility of $0.390 \pm
0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the
mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time
constants associated with the change in mobility during drift of the
$^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron
lifetime in the LXe.
-
We describe a system to transport and identify barium ions produced in liquid
xenon, as part of R&D towards the second phase of a double beta decay
experiment, nEXO. The goal is to identify the Ba ion resulting from an
extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a
confirmation of the occurrence of the decay. This is achieved through Resonance
Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be
produced in liquid xenon or vacuum and collected on a clean substrate. This
substrate is then removed to an analysis chamber under vacuum, where
laser-induced thermal desorption and RIS are used with time-of-flight (TOF)
mass spectroscopy for positive identification of the barium decay product.
-
Using a data sample of $1.31 \times 10^{9}$ $J/\psi$ events accumulated with
the BESIII detector, the decay $J/\psi\to p\bar{p}\phi$ is studied via two
decay modes, $\phi\to K^{0}_{S}K^{0}_{L}$ and $\phi\to K^{+}K^{-}$. The
branching fraction of $J/\psi\to p\bar{p}\phi$ is measured to be
$\mathcal{B}(J/\psi\to
p\bar{p}\phi)=[5.23\pm0.06(\mbox{stat})\pm0.33(\mbox{syst})]\times10^{-5}$,
which agrees well with a previously published measurement, but with a
significantly improved precision. No evident enhancement near the $p\bar{p}$
mass threshold, denoted as $X(p\bar{p})$, is observed, and the upper limit on
the branching fraction of $J/\psi\to X(p\bar{p})\phi\to p\bar{p}\phi$ is
determined to be $\mathcal{B}(J/\psi\to
X(p\bar{p})\phi\to p\bar{p}\phi)<2.1\times10^{-7}$ at the 90\% confidence
level.
-
Based on 2.93 fb$^{-1}$ $e^+e^-$ collision data taken at center-of-mass
energy of 3.773 GeV by the BESIII detector, we report searches for the singly
Cabibbo-suppressed decays $D^{+}\to\omega\pi^{+}$ and $D^{0}\to\omega\pi^{0}$.
A double tag technique is used to measure the absolute branching fractions
$\mathcal{B}(D^{+}\to\omega\pi^{+})=(2.79\pm0.57\pm0.16)\times 10^{-4}$ and
$\mathcal{B}(D^{0}\to\omega\pi^{0})=(1.17\pm0.34\pm0.07)\times 10^{-4}$, with
statistical significances of $5.5\sigma$ and $4.1\sigma$, respectively. We also
present measurements of the absolute branching fractions for the related $\eta
\pi$ decay modes. We find
$\mathcal{B}(D^{+}\to\eta\pi^{+})=(3.07\pm0.22\pm0.13)\times10^{-3}$ and
$\mathcal{B}(D^{0}\to\eta\pi^{0})=(0.65\pm0.09\pm0.04)\times10^{-3}$, which are
consistent with the current world averages. The first and second uncertainties
are statistical and systematic, respectively.
-
The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires
extremely low background and a good understanding of their sources and their
influence on the rate in the region of parameter space relevant to the
0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and
{\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta}
experiment. With this work we try to better understand the location and
strength of specific background sources and compare the conclusions to
radioassay results taken before and during detector construction. Finally, we
discuss the implications of these studies for EXO-200 as well as for the
next-generation, tonne-scale nEXO detector.
-
Using a sample of $2.25\times 10^8$ $J/\psi$ events collected with the BESIII
detector at the BEPCII collider, we search for the $J/\psi$ semi-leptonic weak
decay $J/\psi \to D^{-}_{s} e^{+}\nu_{e}+c.c.$ with a much higher sensitivity
than previous searches. We also perform the first search for $J/\psi \to
D^{*-}_{s} e^{+}\nu_{e}+c.c.$ No significant excess of a signal above
background is observed in either channel. At the $90\%$ confidence level, the
upper limits are determined to be $\mathcal{B}(J/\psi \to
D^{-}_{s}e^{+}\nu_{e}+c.c.)<1.3\times10^{-6}$ and $\mathcal{B}(J/\psi \to
{D^{*}_{s}}^{-}e^{+}\nu_{e}+c.c.)<1.8\times10^{-6}$, respectively. Both are
consistent with Standard Model predictions.
-
EXO-200 is a single phase liquid xenon detector designed to search for
neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for
various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe.
A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the
half-life of the spectral index = 1 Majoron decay was obtained, corresponding
to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee}
>|<$ (0.8-1.7)$\cdot$10$^{-5}$.
-
Progress on a method of barium tagging for the nEXO double beta decay
experiment is reported. Absorption and emission spectra for deposits of barium
atoms and ions in solid xenon matrices are presented. Excitation spectra for
prominent emission lines, temperature dependence and bleaching of the
fluorescence reveal the existence of different matrix sites. A regular series
of sharp lines observed in Ba$^+$ deposits is identified with some type of
barium hydride molecule. Lower limits for the fluorescence quantum efficiency
of the principal Ba emission transition are reported. Under current conditions,
an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba
atoms in solid xenon are discussed.
-
Many extensions of the Standard Model of particle physics suggest that
neutrinos should be Majorana-type fermions, but this assumption is difficult to
confirm. Observation of neutrinoless double-beta decay ($0\nu \beta \beta$), a
spontaneous transition that may occur in several candidate nuclei, would verify
the Majorana nature of the neutrino and constrain the absolute scale of the
neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA
experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have
established the lifetime of this decay to be longer than $10^{25}$ yr,
corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new
results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure,
representing an almost fourfold increase from our earlier published datasets.
We have improved the detector resolution at the $^{136}$Xe double-beta-decay
Q-value to $\sigma$/E = 1.53% and revised the data analysis. The obtained
half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of
2.7 compared to previous EXO-200 results. We find no statistically significant
evidence for $0\nu \beta \beta$ decay and set a half-life limit of
$1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further
running of the EXO-200 detector and future $0\nu \beta \beta$ decay searches
with nEXO.
-
In order to further enhance the particle identification capability of the
Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap
time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC).
The prototypes, together with the front end electronics (FEE) and time
digitizer (TDIG) module have been tested at the E3 line of Beijing Electron
Positron Collider (BEPCII) to study the difference between the single and
double-end readout MRPC designs. The time resolutions (sigma) of the single-end
readout MRPC are 47/53 ps obtained by 600 MeV/c proton/pion beam, while that of
the double-end readout MRPC is 40 ps (proton beam). The efficiencies of three
MRPC modules tested by both proton and pion beam are better than 98%. For the
double-end readout MRPC, no incident position dependence is observed.
-
We report on an improved measurement of the 2\nu \beta \beta\ half-life of
Xe-136 performed by EXO-200. The use of a large and homogeneous time projection
chamber allows for the precise estimate of the fiducial mass used for the
measurement, resulting in a small systematic uncertainty. We also discuss in
detail the data analysis methods used for double-beta decay searches with
EXO-200, while emphasizing those directly related to the present measurement.
The Xe-136 2\nu \beta \beta\ half-life is found to be 2.165 +- 0.016 (stat) +-
0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any
2\nu \beta \beta\ decay to date.