-
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
We describe the purification of xenon from traces of the radioactive noble
gas radon using a cryogenic distillation column. The distillation column is
integrated into the gas purification loop of the XENON100 detector for online
radon removal. This enabled us to significantly reduce the constant $^{222}$Rn
background originating from radon emanation. After inserting an auxiliary
$^{222}$Rn emanation source in the gas loop, we determined a radon reduction
factor of R > 27 (95% C.L.) for the distillation column by monitoring the
$^{222}$Rn activity concentration inside the XENON100 detector.
-
The optical absorption of CdWO$_4$ is reported at high pressures up to 23
GPa. The onset of a phase transition was detected at 19.5 GPa, in good
agreement with a previous Raman spectroscopy study. The crystal structure of
the high-pressure phase of CdWO$_4$ was solved at 22 GPa employing
single-crystal synchrotron x-ray diffraction. The symmetry changes from space
group $P$2/$c$ in the low-pressure wolframite phase to $P2_1/c$ in the
high-pressure post-wolframite phase accompanied by a doubling of the unit-cell
volume. The octahedral oxygen coordination of the tungsten and cadmium ions is
increased to [7]-fold and [6+1]-fold, respectively, at the phase transition.
The compressibility of the low-pressure phase of CdWO$_4$ has been reevaluated
with powder x-ray diffraction up to 15 GPa finding a bulk modulus of $B_0$ =
123 GPa. The direct band gap of the low-pressure phase increases with
compression up to 16.9 GPa at 12 meV/GPa. At this point an indirect band gap
crosses the direct band gap and decreases at -2 meV/GPa up to 19.5 GPa where
the phase transition starts. At the phase transition the band gap collapses by
0.7 eV and another direct band gap decreases at -50 meV/GPa up to the maximum
measured pressure. The structural stability of the post-wolframite structure is
confirmed by \textit{ab initio} calculations finding the post-wolframite-type
phase to be more stable than the wolframite at 18 GPa. Lattice dynamic
calculations based on space group $P2_1/c$ explain well the Raman-active modes
previously measured in the high-pressure post-wolframite phase. The
pressure-induced band gap crossing in the wolframite phase as well as the
pressure dependence of the direct band gap in the high-pressure phase are
further discussed with respect to the calculations.
-
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the $\beta$-emitter
$^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon $\rm{^{nat}}$Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10$^{-15}$ mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.4$\cdot$10$^5$ with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of $\rm{^{nat}}$Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN.
-
A Rn-220 source is deployed on the XENON100 dark matter detector in order to
address the challenges in calibration of tonne-scale liquid noble element
detectors. We show that the Pb-212 beta emission can be used for low-energy
electronic recoil calibration in searches for dark matter. The isotope spreads
throughout the entire active region of the detector, and its activity naturally
decays below background level within a week after the source is closed. We find
no increase in the activity of the troublesome Rn-222 background after
calibration. Alpha emitters are also distributed throughout the detector and
facilitate calibration of its response to Rn-222. Using the delayed coincidence
of Rn-220/Po-216, we map for the first time the convective motion of particles
in the XENON100 detector. Additionally, we make a competitive measurement of
the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For $^{124}$Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of $^{124}$Xe using
7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
$T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
-
We report on WIMP search results of the XENON100 experiment, combining three
runs summing up to 477 live days from January 2010 to January 2014. Data from
the first two runs were already published. A blind analysis was applied to the
last run recorded between April 2013 and January 2014 prior to combining the
results. The ultra-low electromagnetic background of the experiment, ~$5 \times
10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic
recoil rejection, together with the increased exposure of 48 kg $\times$ yr
improves the sensitivity. A profile likelihood analysis using an energy range
of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic,
spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8
GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and
90% confidence level. We also report updated constraints on the elastic,
spin-dependent WIMP-nucleon cross sections obtained with the same data. We set
upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0
$\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50
GeV/$c^2$, at 90% confidence level.
-
We present the first results of searches for axions and axion-like-particles
with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$,
has been probed by exploiting the axio-electric effect in liquid xenon. A
profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has
shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times
10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on
this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions
heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For
axion-like-particles, under the assumption that they constitute the whole
abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than
$1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set
the best limit to date as well.
-
We perform a low-mass dark matter search using an exposure of
30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a
scintillation signal and using only the ionization signal to determine the
interaction energy, we lowered the energy threshold for detection to 0.7\,keV
for nuclear recoils. No dark matter detection can be claimed because a complete
background model cannot be constructed without a primary scintillation signal.
Instead, we compute an upper limit on the WIMP-nucleon scattering cross section
under the assumption that every event passing our selection criteria could be a
signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a
limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs
with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\%
confidence level.
-
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
-
This document presents the Conceptual Design Report (CDR) put forward by an
international neutrino community to pursue the Deep Underground Neutrino
Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking
science experiment for long-baseline neutrino oscillation studies and for
neutrino astrophysics and nucleon decay searches. The DUNE far detector will be
a very large modular liquid argon time-projection chamber (LArTPC) located deep
underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE
will also have a high-resolution and high-precision near detector.
-
The Daya Bay experiment was the first to report simultaneous measurements of
reactor antineutrinos at multiple baselines leading to the discovery of
$\bar{\nu}_e$ oscillations over km-baselines. Subsequent data has provided the
world's most precise measurement of $\rm{sin}^22\theta_{13}$ and the effective
mass splitting $\Delta m_{ee}^2$. The experiment is located in Daya Bay, China
where the cluster of six nuclear reactors is among the world's most prolific
sources of electron antineutrinos. Multiple antineutrino detectors are deployed
in three underground water pools at different distances from the reactor cores
to search for deviations in the antineutrino rate and energy spectrum due to
neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water
pools serve as shielding against natural radioactivity from the surrounding
rock and provide efficient muon tagging. Arrays of resistive plate chambers
over the top of each pool provide additional muon detection. The antineutrino
detectors were specifically designed for measurements of the antineutrino flux
with minimal systematic uncertainty. Relative detector efficiencies between the
near and far detectors are known to better than 0.2%. With the unblinding of
the final two detectors' baselines and target masses, a complete description
and comparison of the eight antineutrino detectors can now be presented. This
paper describes the Daya Bay detector systems, consisting of eight antineutrino
detectors in three instrumented water pools in three underground halls, and
their operation through the first year of eight detector data-taking.
-
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
-
We report a new measurement of electron antineutrino disappearance using the
fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight
antineutrino detectors were installed in the summer of 2012. Including the 404
days of data collected from October 2012 to November 2013 resulted in a total
exposure of 6.9$\times$10$^5$ GW$_{\rm th}$-ton-days, a 3.6 times increase over
our previous results. Improvements in energy calibration limited variations
between detectors to 0.2%. Removal of six $^{241}$Am-$^{13}$C radioactive
calibration sources reduced the background by a factor of two for the detectors
in the experimental hall furthest from the reactors. Direct prediction of the
antineutrino signal in the far detectors based on the measurements in the near
detectors explicitly minimized the dependence of the measurement on models of
reactor antineutrino emission. The uncertainties in our estimates of
$\sin^{2}2\theta_{13}$ and $|\Delta m^2_{ee}|$ were halved as a result of these
improvements. Analysis of the relative antineutrino rates and energy spectra
between detectors gave $\sin^{2}2\theta_{13} = 0.084\pm0.005$ and $|\Delta
m^{2}_{ee}|= (2.42\pm0.11) \times 10^{-3}$ eV$^2$ in the three-neutrino
framework.
-
We propose a nanowaveguide platform for collective atom-light interaction
through evanescent field coupling. We have developed a 1cm-long silicon nitride
nanowaveguide can use evanescent fields to trap and probe an ensemble of 87Rb
atoms. The waveguide has a sub-micrometer square mode area and was designed
with tapers for high fiber-to-waveguide coupling efficiencies at near-infrared
wavelengths (750nm to 1100nm). Inverse tapers in the platform adiabatically
transfer a weakly guided mode of fiber-coupled light into a strongly guided
mode with an evanescent field to trap atoms and then back to a weakly guided
mode at the other end of the waveguide. The coupling loss is -1dB per facet
(~80% coupling efficiency) at 760nm and 1064nm, which is estimated by a
propagation loss measurement with waveguides of different lengths. The proposed
platform has good thermal conductance and can guide high optical powers for
trapping atoms in ultra-high vacuum. As an intermediate step, we have observed
thermal atom absorption of the evanescent component of a nanowaveguide, and
have demonstrated the U-wire mirror magneto-optical trap that can transfer
atoms to the proximity of the surface.
-
This Letter reports a measurement of the flux and energy spectrum of electron
antineutrinos from six 2.9~GW$_{th}$ nuclear reactors with six detectors
deployed in two near (effective baselines 512~m and 561~m) and one far
(1,579~m) underground experimental halls in the Daya Bay experiment. Using 217
days of data, 296,721 and 41,589 inverse beta decay (IBD) candidates were
detected in the near and far halls, respectively. The measured IBD yield is
(1.55 $\pm$ 0.04) $\times$ 10$^{-18}$~cm$^2$/GW/day or (5.92 $\pm$ 0.14)
$\times$ 10$^{-43}$~cm$^2$/fission. This flux measurement is consistent with
previous short-baseline reactor antineutrino experiments and is $0.946\pm0.022$
($0.991\pm0.023$) relative to the flux predicted with the Huber+Mueller
(ILL+Vogel) fissile antineutrino model. The measured IBD positron energy
spectrum deviates from both spectral predictions by more than 2$\sigma$ over
the full energy range with a local significance of up to $\sim$4$\sigma$
between 4-6 MeV. A reactor antineutrino spectrum of IBD reactions is extracted
from the measured positron energy spectrum for model-independent predictions.
-
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
-
We have measured the scintillation and ionization yield of recoiling nuclei
in liquid argon as a function of applied electric field by exposing a
dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy
pulsed narrow band neutron beam produced at the Notre Dame Institute for
Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged
to detect and identify neutrons scattered in the TPC and to select the energy
of the recoiling nuclei. We report measurements of the scintillation yields for
nuclear recoils with energies from 10.3 to 57.3 keV and for median applied
electric fields from 0 to 970 V/cm. For the ionization yields, we report
measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486
V/cm. We also report the observation of an anticorrelation between
scintillation and ionization from nuclear recoils, which is similar to the
anticorrelation between scintillation and ionization from electron recoils.
Assuming that the energy loss partitions into excitons and ion pairs from
$^{83m}$Kr internal conversion electrons is comparable to that from $^{207}$Bi
conversion electrons, we obtained the numbers of excitons ($N_{ex}$) and ion
pairs ($N_i$) and their ratio ($N_{ex}/N_i$) produced by nuclear recoils from
16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in
LAr-TPC signals due to columnar recombination, a comparison of the light and
charge yield of recoils parallel and perpendicular to the applied electric
field is presented for the first time.
-
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
-
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
-
A search for light sterile neutrino mixing was performed with the first 217
days of data from the Daya Bay Reactor Antineutrino Experiment. The
experiment's unique configuration of multiple baselines from six 2.9~GW$_{\rm
th}$ nuclear reactors to six antineutrino detectors deployed in two near
(effective baselines 512~m and 561~m) and one far (1579~m) underground
experimental halls makes it possible to test for oscillations to a fourth
(sterile) neutrino in the $10^{\rm -3}~{\rm eV}^{2} < |\Delta m_{41}^{2}| <
0.3~{\rm eV}^{2}$ range. The relative spectral distortion due to electron
antineutrino disappearance was found to be consistent with that of the
three-flavor oscillation model. The derived limits on $\sin^22\theta_{14}$
cover the $10^{-3}~{\rm eV}^{2} \lesssim |\Delta m^{2}_{41}| \lesssim 0.1~{\rm
eV}^{2}$ region, which was largely unexplored.
-
A new measurement of the $\theta_{13}$ mixing angle has been obtained at the
Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays
tagged by neutron capture on hydrogen. The antineutrino events for hydrogen
capture are distinct from those for gadolinium capture with largely different
systematic uncertainties, allowing a determination independent of the
gadolinium-capture result and an improvement on the precision of $\theta_{13}$
measurement. With a 217-day antineutrino data set obtained with six
antineutrino detectors and from six 2.9 GW$_{th}$ reactors, the rate deficit
observed at the far hall is interpreted as $\sin^22\theta_{13}=0.083\pm0.018$
in the three-flavor oscillation model. When combined with the
gadolinium-capture result from Daya Bay, we obtain
$\sin^22\theta_{13}=0.089\pm0.008$ as the final result for the
six-antineutrino-detector configuration of the Daya Bay experiment.
-
We reported here a high-performance In2O3/InZnO bilayer metal-oxide (BMO)
thin-film transistor (TFT) using ultra-thin solution-processed ZrOx dielectric.
A thin layer of In2O3 offers a higher carrier concentration, thereby maximizing
the charge accumulation and yielding high carrier mobility. A thick layer of
InZnO controls the charge conductance resulting in low off-state current and
suitable threshold voltage. As a consequence, the BMO TFT showed higher
filed-effect mobility (37.9 cm2/V s) than single-layer InZnO TFT (7.6 cm2/V s).
More importantly, an on/off current ratio of 109, a subthreshold swing voltage
of 120 mV/decade, as well as a threshold voltage shift (less than 0.4 V) under
bias stress for 2.5 hours were obtained simultaneously. These promising
properties are obtained at a low operation voltage of 3 V. This work
demonstrates that the BMO TFT has great potential applications as switching
transistor and low-power devices.